|
Facilité d'utilisation
Contact your Sears salesperson to arrange for a professional electrician, AWARNING WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equipped for one type volt age only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any voltage other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company. A CAUTION If wiring from your fuse box or circuit breaker box was aluminum for your old water heater, replace it with cop per wire. If you wish to reuse the existinS aluminum wire, have the connection at the water heater made by a com petent electrician. Contact your Sears salesperson to arrange for a professional electrician. 1. Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch, 2, Install and connect a circuit directly from the main fuse or circuit breaker box, This circuit must be the right size and have its own fuse or circuit breaker. Refer to the chart in the "Product Specifications" section for the correct size wire and fuse circuit breaker, 3. If metal conduit is used for the grounding conductor: A. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum, The material shall be of one continuous length without a splice or joint. B. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding. C. Flexible metal conduit or flexible metallic tubing shall be permitted for grounding if all the following conditions are met: I. The length in any ground return path does not exceed 6 feet. 2. The circuit conductors contained therein are protected byovercurrentdevicesrated at20amperesorless. 3. The conduit or tubing is terminated in fittings approved for grounding• For complete grounding details and all allowable exceptions, refer to the latest edition of the National Electrical Code. 4. A standard . condmt opening has been made in the water heater junction box for the conduit connection. 5. Wiring Diagrams (See W_zring Diagrams Section) have been supplied showing the two most common types of connections between the water heater and the power supply, You can easily see which type connection you have by removing the junction box cover on top of the water heater. Two Wire Connection Diagrams: is the most common requiring you to simply connect red to red, black to black, and the groundwire to the greenground screw in the junc tion box of the waterheater. NOTE: If you have purchased a three wire connection water heater but you are not on a "Time Clock" or "Off Peak" meter and have a stand_d two wite connection Tower supply, simply follow the connection diagram in lock 3. of the ThreeWL,'eConnection Diagram. 6. Use wire nuts and connect the power supply wiring to the wires inside the water heaters junct'on. 7. The water heater must be electrically "grounded" by the installer. A greer_ ground screw has been provided oft the water heater's junction box. Connect ground wire to this location. 8. Replace the wiring junction cover using the screw provided. WIRE NUTS CONDUIT SCREW 14 Installation Instructions (cont'd) Installation Checklist HOT • Whether or not the element conversion is made, the model rating plate must be marked.Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the loweraccesspanel. • Is the fiase or circuit breaker size correct as shown in the chart in the "Product Specifications" section? • Are the wires from the circuit breaker or fuse service to the water heater's 'unction box on the correct wire size (gauge) as shown in the chart in the "Product Specifications" section? • Is the new temperature-pressure relief valve properly installed, and piped to an adequate drain? See "Temperature-Pressure Relief Valve" section. • Is the water heater completely filled with water? See "Filling the Water Heater" instructions in the "Installation Instructions sect on. • Wdl a water leak damage anything? See "Facts to Consider About the Location" section. • Are the cold and hot water lines connected to the water heater correctly?gee "Water Piping" instructions in the "Installation Instructions"section• • Is there adequate clearance for maintenance around the water heater? • Do you r_eed to call your electric company to check your wiring? COLD TEMPERATUREPRESSURE RELIEF VALVE PIPE (Do not cap or plug) 6" AIR GAP MODEL RATING PLATE 15 Service and Adjustment Temperature Regulation A WARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, ...
Ce manuel est également adapté pour les modèles :Sounders - 153.31206 (1.05 mb)
Sounders - 153.31614 (1.05 mb)
Sounders - 153.327240HT (1.05 mb)