Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Regency, Modèle SSDVT-3328CNM

Fabricant : Regency
Taille : 2.03 mb
Nom Fichier : 68933604-62bd-4b12-9332-981228318024.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Toggle the switch from ON to OFF to operate the main burner. Variable Flame Height Adjustment (Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings while the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob (HI/LO) located on the front of the valve (refer to Figures 4 & 5). 2. During the first initial burns of these appliances, there will be some odor emitted (see Burn-In Period on Page 3 ). 3. Keep the lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, pet hair, etc. It is very important that the control compartments, burners and circulating air passageways of the appliance are kept clean. 4. Always turn off gas to the pilot (millivolt appliances) and let the appliance cool down before cleaning. Before re-lighting, refer to the lighting instructions in this manual. Lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. 5. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids. 6. Remember, Millivolt appliances have a continuous burning pilot flame. Exercise caution when using products with combustible vapors. SIT Millivolt Gas Valve SIT Gas Valve HILOWHTPTHTPTPILOTPILOTONtiOFFINOUTOFFONOFFON HI/LO Variable Flame Height Adjustment Manifold Pressure Tap Gas Inlet Inlet Pressure Tap Shown with control compartment door removed Gas Outlet Pilot Adjustment Screw Honeywell Gas Valve Terminals TPTH,TP & TH Piezo Igniter Piezo Igniter Sit and Honeywell Millivolt Gas Valve Showing Piezo Igniter Location (Each Unit is Equipped with Only One of these Gas Valves) Main Gas Control Knob OFF/PILOT/ON Figure 2 Optional Burner OFF/ON Rocker Switch Optional Blower OFF/ON Rocker Switch Piezo Igniter Electronic Appliances - To light electronic appliances refer to the detailed lighting instructions found on Pages 18 & 19 of these instructions. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Figure 4 Honeywell Millivolt Gas Valve ONOFFPILOTLOHIOFFONOFFON Gas Outlet Inlet Pressure Tap Manifold Pressure Tap Piezo Igniter Honeywell Electronic Gas Valve Manifold Pressure Port ON / OFF Switch FFONIPSINOLORTNOCGINTIER Inlet Pressure Port Piezo Igniter Gas Inlet Main Gas Control Knob OFF/PILOT/ON HI/LO Variable Flame Height Adjustment Optional Blower OFF/ON Rocker Switch Optional Burner OFF/ON Rocker Switch Figure 5 Electronic Gas Control Valve Figure 3 Clean Logs And Burner Carefully remove the logs (use care when handling the fiber logs, as they become quite fragile after curing). Vacuum out any foreign matter (lint, carbon, etc). on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the under side of the logs using a vacuum cleaner, or a soft bristled brush (i.e. paint brush). Note: Improper positioning of logs can create carbon build-up and will alter the performance of the appliance. Replacing Logs - If the logs become damaged by accident or improper handling and need replacement, use only the proper replacement logs from manufacturer (see Page 23 for ordering information). Re-Install Embers, Logs and Volcanic Stone - Carefully follow placement instructions on Pages 7 to 9 ). All logs should fit onto corresponding pins and/or log stoppers. This will ensure a proper flame and safe combustion. Inspect Wiring Refer to wiring diagrams on Page 11. MAINTENANCE (See Maintenance Schedule, Page 20) Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper operation of the appliance after servicing. Before re-lighting the fireplace, refer to the lighting instructions in this manual. Instructions are also found on pull-out panels located below the glass door in the control compartment. IMPORTANT It is imperative that the control compartment, burners and circulating air passage ways of appliance be kept clean. Cleaning Glass (see Front Glass Enclosure Panel, Removal and Installation on Pages 6). Note: Clean glass after first two weeks of operation (after Burn-In period is over) and then only when necessary and when the fireplace is cool. Wipe surface with clean, dampened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface. The viewing glass should be cleaned periodically to remove any build-up caused from the following: WARNING Turn off gas and electrical power before servicing the appliance. CAUTION Wear gloves and safety Glasses for protection while doing required maintenance. IMPORTANT Do not use abrasive cleaners on glass...

Ce manuel est également adapté pour les modèles :
Cheminées - SSDVT-3328CNM (2.03 mb)
Cheminées - SSDVT-3328CNM (2.03 mb)
Cheminées - SSDVT-3328CNM (2.03 mb)
Cheminées - SSDVT-3328CNM (2.03 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories