Log:
Évaluations - 2, GPA: 3 ( )

Instructions Dimplex, Modèle EBY15

Fabricant : Dimplex
Taille : 1.24 mb
Nom Fichier : 1db9d898-d40a-4b2e-990f-0d95edd959d5.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


3B. When the hook is securely fastened, position the top outer slot on the fire (see Fig. 3B) alongside the hook, lift the fire up and over the hook so that the top outer slot on the fire engages the hook. Electrical connection WARNING – THIS APPLIANCE MUST BE EARTHED. This heater must be used on an AC ~ supply only and the voltage marked on the heater must correspond to the supply voltage. Before switching on, please read the safety warnings and operating Instructions. Controls - see Fig. 6 The product can be controlled both manually and by remote control. Manual Controls The fire controls are located at the base of the fire behind the bottom fret - see Fig. 5. To gain access to controls, remove fret by pulling outwards using fret knob. Two switches and a thermostat knob provide a choice of fire settings see Fig. 6. The red indicator mark on the switch will be visible when it is turned on. Switch B Controls the electricity supply to the heater. Note: This switch must be in the ON position for the heater to operate with or without heat. Switch A Controls the function of the fire. Press once to give flame effect only. Press again to give heat and flame effect. Press again to go back to flame effect only. Pressing ‘O’ at any stage turns the fire to standby mode. Note: To turn fire completely off use switch B. Thermostat In order to maintain a certain room temperature, set the controller to ‘max.’. Operate the appliance at full power until the required room temperature is reached. Set back the thermostatic controller until the appliance switches off. This temperature will be kept almost constant by the thermostatic control switching on and off automatically.Please note that the appliance can only be switched on when the thermostat setting is higher then the room temperature. Initializing the Remote Control Note: The remote control is packed separately in the carton. 1. Slide open the battery cover on the back of the remote transmitter. 2. Install the AAA batteries into the remote control (see Fig. 9). 3. Replace battery cover. Dispose of batteries in the proper manner according to Provincial and local regulations. Any battery may leak electrolyte if mixed with a different battery type, if inserted incorrectly, if all the batteries are not replaced at the same time, if disposed of in a fire or if an attempt is made to charge a battery not intended to be recharged. Remote Control Operation Cleaning Warning: It takes some time for the receiver to respond to the transmitter. Do not press the buttons more than once within two seconds for correct operation. On the control panel, switch B must be in the ‘ON’ position in order for the PCB to operate. Setting Operation Flame effect Press ‘I’ button once Flame effect and heat Press ‘I’ button again By continuously pressing the ‘I’ button the fire will cycle between flame effect and flame effect plus heat. To turn off any of the settings press the ‘O’ button once. The remote control may be placed, when not in use, in the wall-mounted holster provided (see Fig. 10). Thermal Safety Cut-out For your safety, this appliance has been fitted with thermal cut-out. In the event that the product overheats, the cut-out switches the appliance off automatically. To bring the appliance back into operation, remove the cause of the overheating, then unplug or turn off the electrical supply to the heater for up to 10 minutes. When the heater has cooled sufficiently, re-connect and switch on the heater. Caution: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. Maintenance WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE. Lamp Replacement - see Fig.’s 7 & 8 There are two lamps located beneath the fuel effect. To gain access to the lamps, remove the coal and place in a container. Remove the grate/ fuel effect by unscrewing the two screws, lift away the grate/fuel effect to allow access to the bulbs - see Fig. 7. Remove the defective lamp by unscrewing it as shown in Fig. 8. Replace with a 60W E14 SES Clear Candle lamp. Take care not to overtighten the lamp. Refit the fuel effect and replace the coal. WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER. For general cleaning use a soft clean duster – never use abrasive cleaners. The glass viewing screen should be cleaned carefully with a soft cloth. DO NOT use proprietary glass cleaners. To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of the fan heater. Recycling For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories