Log:
Évaluations - 5, GPA: 3.4 ( )

Instructions New Buck Corporation, Modèle 384

Fabricant : New Buck Corporation
Taille : 1.14 mb
Nom Fichier : 5c007394-15c9-451d-9c0a-197b11e33b9d.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Fully open the manual shutoff valve. 8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue pressing in the knob for (15) fifteen seconds. 9. With control knob pressed in push down (in) and release the ignitor button (ignitor button is located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep repeating this step until pilot lights. 10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1 through 9. Page 14 * If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn control knob counterclockwise lZ^ to “ON”. 12. If using unit without wall thermostat place Auto/Off/Manual switch into the manual position. If using wall thermostat place Auto/Off/Manual Switch into the auto position and place thermostat to a setting higher than the room temperature. 13. Close access cover door. 14. “Turn on all electrical power to the appliance.” 15. Your heater is equipped with a HI & LO control. Turn clockwise for Low and counterclockwise for High. CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1. Open access cover door. 2. “If equipped with thermostat set to lowest setting.” 3. Turn control knob clockwise :— :—to the full “OFF”. 4. Turn off all electric power to the appliance if service is to be performed. 5. Close access cover door. SHUTTING OFF BURNER ONLY (Pilot stays lit.) Turn control knob clockwise to the “PILOT” position. CAUTION: Hot while in operation. Do Not Touch. Keep children, clothing, furniture, gasoline, and other liquids having flammable vapors away. CAUTION: DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or loss of life. Refer to owner’s information manual provided with this appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. IMPORTANT: Always operate the appliance at the completely “ON” or the completely “OFF” positions. Never use the heater at a setting between these positions as this can result in improper combustion and excessive carbon monoxide emissions. Page 15 MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2. Open access panel door located at bottom front of the appliance. 3. Place the match in the holder and light. With the left hand, turn the control knob counterclockwise i to “PILOT”position. Press in gas control knob for fifteen (15) seconds. 4. Use rod to light match and ignite pilot. The pilot is located in front of the rear log and burner on the right hand side of the appliance. 5. Continue to hold the control knob for an additional one (1) minute to ensure the pilot is lit. 6. Turn control knob counterclockwise =<: lH: to the “ON” position. Push the “ON/ OFF” toggle switch to the “ON” position. The main burner should light. 7. Close access panel door. 8. Turn on all electrical power to the appliance. NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat needs to be set at a higher temperature than the room temperature. Page 16 FLAME CHECK A periodic check of the flames should be made. The pilot flame should always be present when the gas logs are in operation. Rear Flames: The flames at the rear or at either side of the top log should be very similar, yellow in color, and should be about 3" to 4" above the large rear log for natural gas logs and about 6" for propane (LP) gas log sets. Front Flame: The flame should be 1-1/2" to 2" high and touch the back of front log. This will produce a red glow on this log. CR 3329 LOG SET APPLIANCE HEAT OUTPUT When used as a ventless heater, the flue damper of a solid-fuel burning non-combustible fireplace must always be closed. The heat output is controlled by the “ON/OFF” switch or wall thermostat, when using the Millivolt Valve. When using the -SIT Modulating or -SIT Manual Valve the heat output is controlled by the dial with LOW to HIGH settings. The Vent-Free fireplace may be installed where permitted by local, state, and city codes. In the absence of local codes, the latest edition of the National Fuel Gas Code (ANSI Z223.1) must be met. Page 17 WIRING DIAGRAM THERMOSTAT Figure 5 WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE_ WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON O...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories