Log:
Évaluations - 5, GPA: 3.6 ( )

Instructions New Buck Corporation, Modèle MODEL FP-327-ZC

Fabricant : New Buck Corporation
Taille : 1.29 mb
Nom Fichier : b2dbe6ef-de2e-4e94-bce4-5f305b565f85.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


4. Open access panel door located at bottom front of the appliance. 5. Turn control knob clockwise to the full “OFF” position. When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing wires, simply add the wire from the Wall Thermostat to screws (one wire to each screw). 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety informationon the previous page.If you don’t smell gas, go to the next step. 7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of the appliance. Fully open the manual shutoff valve. 8. Push the ON/OFF toggle switch to “OFF” (rocker switch). 9. Turn gas control knob counterclockwise to the “PILOT” position.Press in gas control knob for fifteen (15) seconds. 10. With control knob pressed in , push down (in) and release the ignitor button (ignitor button is located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep repeating this step until pilot lights. 11. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1 through 9. • If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. PILOT BURNER IGNITOR ELECTRODE PILOT ONOFF BEFORE INSTALLING THERMOSTAT REMOVE METAL CONNECTOR PIEZO ROCKER SWITCH BURNER PILOT ASS'Y THERMOSTAT ITT VALVE THERMO GEN AUX PRESSTORESETOFF PILOT ON ITTGENERAL CONTROLS PILOTADJ THERMOPILE CONTROL KNOB 9080706050 When hooking up a Wall Thermostat to valve, remove the Jumper Bar. Do not remove the existing wires, simply add the wire from the Wall Thermostat to screws (one wire to each screw). 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety informationon the previous page.If you don’t smell gas, go to the next step. 7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of the appliance. Fully open the manual shutoff valve. 8. Push the ON/OFF toggle switch to “OFF” (rocker switch). 9. Turn gas control knob counterclockwise to the “PILOT” position.Press in gas control knob for fifteen (15) seconds. 10. With control knob pressed in , push down (in) and release the ignitor button (ignitor button is located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep repeating this step until pilot lights. 11. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute, release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 1 through 9. • If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. PILOT BURNER IGNITOR ELECTRODE PILOT ONOFF BEFORE INSTALLING THERMOSTAT REMOVE METAL CONNECTOR PIEZO ROCKER SWITCH BURNER PILOT ASS'Y THERMOSTAT ITT VALVE THERMO GEN AUX PRESSTORESETOFF PILOT ON ITTGENERAL CONTROLS PILOTADJ THERMOPILE CONTROL KNOB 9080706050 Page 22 • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 12. Turn control knob counterclockwise to the “ON” position. Push the “ON/OFF” toggle switch to the “ON” position. The main burner should light. 13. Close access panel door. 14. Turn on all electrical power to the appliance. 15. Set thermostat to desired setting. NOTE: This unit may be used with an optional Wall Thermostat. If so, the Wall Thermostat needs to be set at a higher temperature than the room temperature. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1. Open access panel door located at bottom front of the appliance. 2. “If equip with thermostat set to lowest setting.” 3. Turn control knob clockwise to the “OFF” position. 4. Turn off all electric power to the appliance if service is to be performed. 5. Close access panel door. SHUTTING OFF BURNER ONLY (Pilot stays lit.) Turn control knob clockwise to the “PILOT” position. CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. PILOT BURNER IGNITOR ELECTRODE THERMO-PILE PILOT BURNER IGNITOR ELECTRODE THERMO-PILE Page 23 THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat or Remote control. If so, see Figure 2, page 22 for wiring diagram. MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2. Open access panel door located at bottom front of the appliance. 3. 2. Place the match in the holder and light. With the left hand, turn the control knob counterclockwise to “PILOT”position. Press in gas control knob for fifte...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories