4. Check all gas connections for leaks. See Checking Gas Connections, page 23. Propane/LP Supply Tank External Regulator Vent Pointing Down Figure 30 - External Regulator with Vent Pointing Down (Propane/LP Only) Fireplace Installation Continued Red Surface Indicates For Propane/LP Use Only Flexible Gas Line Do NOT Kink Equipment Shutoff Valve 1/2" NPT Incoming Gas Line Inlet Pressure Tap Outlet Pressure Tap Note: Wire Connections Not Shown for Clarity Figure 32 - Connecting Flexible Gas Line to Electronic Valve CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 33). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air. 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34, for propane/LP or Figure 35, for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Equipment Shutoff Valve Open Closed Figure 33 - Equipment Shutoff Valve Equipment Shutoff Valve Propane/LP Supply Tank Gas Valve Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace Equipment Shutoff Valve Gas Meter Gas Valve Figure 35 - Checking Gas Joints for Natural Gas Fireplace Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 33, page 23). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 34, page 23, for propane/LP or Figure 35, page 23, for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, page 28). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 28). Fireplace Installation Continued Louver Panel Spring Latch Figure 36 - Removing Louver Panel Removing/Replacing Glass Door CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 34. CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers. Removing Louver Panels Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above. Removing Glass Door If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame. 1. Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside. 2. Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 37). 3. While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 37). LockUnlock Latch Screw Hinge Glass Frame Assembly Figure 37 - Removing/Replacing Glass Door 4. Remount the new frame at the...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories