Log:
Évaluations - , GPA: ( )

Instructions Desa, Modèle (V)K42P SERIES

Fabricant : Desa
Taille : 5.03 mb
Nom Fichier : 5261d6e0-c2aa-6774-415a-7ed18842c964.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


Mantel Depth Ref. Mantel from Top of Louver Opening 1 14" (356mm) A 16" (406mm) 2 12" (305mm) B 14" (356mm) 3 10" (254mm) C 12" (305mm) 4 8" (203mm) D 10" (254mm) 5 6" (152mm) E 8" (203mm) 6 4" (101mm) F 6" (152mm) 7 2" (51mm) G 4" (101mm) Figure 4 - Framing Clearances for Installation Against an Exterior Wall For more information, visit more information, visit 111921-01D 6 6 LOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAP Fixed Closed Openable Fixed Closed OpenableV V V V V V X X V X G G J F B B K N H I A N E LD B M C B V VA G G B TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (182.9cm) [*12 inches (30.5mc) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building or the [12 inches (30.5cm) minimum] combustion air inlet to any other fireplace [*12 inches (30.5cm) C = clearance to permanently closed window [minimum 12 inches minimum] (30.5cm) recommended to prevent condensation on window] K = clearance to a mechanical air supply inlet [*72 inches (182.9cm) D = vertical clearance to ventilated soffit located above the terminal minimum] within a horizontal distance of 24 inches (61cm) from the L = clearance above paved side-walk or a paved driveway located on center-line of the terminal [18 inches (45.7cm) minimum] public property [*84 inches (213.3cm) minimum] E = clearance to unventilated soffit [12 inches (30.5cm) minimum] M = clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ] F = clearance to outside corner (see below) N = clearance above a roof shall extend a minimum of 24 inches (61cm) G = clearance to inside corner (see below) above the highest point when it passes through the roof surface and H = *not to be installed above a meter/regulator assembly within any other obstruction within a horizontal distance of 18 inches (45.7cm) 36 inches (91.4cm) horizontally from the center-line of the regulator vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances Termination Clearances for Buildings with Combustible and Noncombustible Exteriors Inside Corner Outside Corner Recessed Location V A A = 6" (15.2cm) V B B = 6" (15.2cm) Balcony with No Side Wall Balcony with Perpendicular Side Wall V G H G = 12" (30.5cm) minimum clearance V J Combustible & Noncombustible H = 24" (61cm) J = 20" (50.8cm) C = Maximum depth of 48" (121.9cm) for recessed location D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm) E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm) C D C Figure 7 - Minimum Clearances for Termination Cap For more information, visit more information, visit 111921-01D VENTING INSTALLATION INSTRUCTIONS Installation Precautions 7 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely before attempting installation. These models are tested and approved for use with DESA (directvent) pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance. These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines: • When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be installed directly on a combustible finish such as vinyl, wood, stucco, etc. • Never run the vent downward as this may cause excessive temperatures which could cause a fire. • Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required. • Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11). • Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces. • Install horizontal venting with a 1/4" rise for every 12" of run toward the termination. WARNING: Read al...

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories