Log:
Évaluations - 5, GPA: 4 ( )

Instructions Vermont Casting, Modèle 43028

Fabricant : Vermont Casting
Taille : 4.19 mb
Nom Fichier : 3f75ba6b-b638-4568-9207-716bcf60a47c.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


2) Turn the LP cylinder so the opening of the valve is either to the front, side or rear of the Weber® gas fireplace. Lift and hook the cylinder onto the fuel gauge. 3) Loosen the cylinder lock wing nut. Swing the cylinder lock down. Tighten the wing nut. To Connect the hose to the cylinder: 4) Remove the plastic dust cover from the valve. 5) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only. Note: This is a new type of connection. It tightens clockwise and will not allow gas to flow unless the connection is tight. The connection requires tightening by hand only. WARNING: Do not use a wrench to tighten the connection. Using a wrench could damage the regulator coupling and could cause a leak. 6) Mix soap and water. 7) Turn on the cylinder valve. 8) Check for leaks by wetting the fitting with the soap and water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is a leak. If there is a leak, turn off the gas and tighten the fitting. Turn the gas back on and recheck with the soap and water solution. If leak does not stop, contact the Customer Service Representative in your area using the contact information on our web site. Log onto . Do not use the fireplace. Installation and repair should be done by a qualified service person. The fireplace should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air passageways of the fireplace be kept clean. 9) When leak checking is complete, turn gas supply OFF at the source and rinse connections with water. GAS INSTRUCTIONS 13 CHECK FOR GAS LEAKS DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for leaks. Sparks or open fl ames will result in a fi re or explosion, which can cause serious bodily injury or death and damage to property. WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fi tting. Note - All factory-made connections have been thoroughly checked for gas leaks. The burner has been fl ame-tested. As a safety precaution however, you should recheck all fi ttings for leaks before using your Weber® Gas Fireplace. Shipping and handling may loosen or damage a gas fi tting. WARNING: Perform these leak checks even if your fi replace was dealer or store assembled. You will need: a soap and water solution, and a rag or brush to apply it. Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks. To perform leak checks: open cylinder valve by turning the cylinder valve hand-wheel counterclockwise. WARNING: Do not ignite burner when leak checking. Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak. Check: 1) Regulator-to-Cylinder connection. WARNING: If there is a leak at connection (1) or (2), retighten the fi tting by hand only, and recheck for leaks with soap and water solution. If a leak persists after retightening the fi tting, turn OFF the gas. DO NOT OPERATE THE FIREPLACE. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto Check: 2) Hose-to-regulator. 3) Hose to bulkhead fi tting. 4) Bulkhead fi tting. WARNING: If there is a leak at connections (2), (3), or (4), turn OFF the gas. DO NOT OPERATE THE FIREPLACE. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto com®. When leak checks are complete, turn gas supply OFF at the source and rinse connections with water. (1) (2) (3) (4) 14 GAS INSTRUCTIONS 14 GAS INSTRUCTIONS REFILLING THE LIQUID PROPANE CYLINDER We recommend that you refill the LP cylinder before it is completely empty. Removal of the LP cylinder 1) Make sure hose is secured in retainer clip. 2) Close cylinder valve (turn clockwise). 3) Unscrew regulator coupling by turning counterclockwise, by hand only. 4) Loosen cylinder lock wing nut and turn cylinder lock up out of the way. 5) Lift cylinder off. To refill, take LP cylinder to a “Gas Propane” dealer. WARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualifi ed attendant, who fills the cylinder by weight. IMPROPER FILLING IS DANGEROUS. CAUTION: When transporting the LP cylinder make sure the plastic dust cover is in place over the valve. This will keep dust and dirt from the threaded portion of the valve. CHECKING THE FUEL LEVEL IN YOUR TANK Check the fuel level by viewing the color indicator level line on the side of the tank scale. 1) Empty 2) Medium 3) Full (3) (4) (2)(1) (1) (2) (3) SAFE HANDLING TIPS FOR LIQUID PROPANE GAS CYLINDERS • Liquid Propane (LP...

Ce manuel est également adapté pour les modèles :
Cheminées - 43028 (4.19 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories