|
Facilité d'utilisation
58 Transmitter diagram. On (Manual) Mode In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons. When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit. Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. Auto Mode In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons. Fan Override During Auto Mode If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon. Change Between F/C Temperature Units Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units. Disable Thermostat Function To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds. To Change Batteries 1. Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover. 2. Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter. 3. Use functions as described in TRANSMITTER section. Troubleshooting 1. Locate LED light on valve. 2. LED will blink after every valid command received by the transmitter; this is not an error. 3. Failure codes may occur anytime after pilot burner is lit. 4. Sequence is failure code followed by light not blinking for 30 seconds. Radiance Direct Vent Gas Heater FAN Antenna Red White Red White Comfort Control Valve (Bottom View) Blower Pilot As- sembly FP1038 Fig. 59 Comfort Valve wiring diagram. White Dots 5. In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds. If an Error Code 3 is observed while performing the testing, complete the following: 1. Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step. 2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles. If an Error Code 8 is observed while performing the testing, complete the following: 1. Confirm the valve is not in REMOTE mode. • If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced. • If the valve is in LOCAL mode and producing Error Code 8, then go to the next step. 2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter. The Error Code will clear itself after approximately 1.5 minutes and return to normal operation. LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 Turn fan ON NOTE: Some keys are not active. 20012697 33 Radiance Direct Vent Gas Heater Comfort Control Valve System Sequence of Operation with Transmitter Light pilot burner Set manual switch to local or remote Release pilotstat knob. Turn pilotstat knob from PILOT to ON. Did the LED stop blinking? Yes No Move switch from local to remote. Press any key on transmitter. Move switch back to local. Five minute wait period Review LED fail- ure analysis. On Path If the manual switch is set to REMOTE, press the mode button to display “ON”. does transmitter control the main burner and fan? Yes Move switch from manual to remote. Press any key on transmitter. Does transmitter No change levels of flame height, fan speed? Yes Cycle switch once and leave in remote. Press any key on transmitter for recognition operation. Choose Manual or Remote path. Set switch t...
Ce manuel est également adapté pour les modèles :Cheminées - RADVTSG (4.03 mb)
Cheminées - RADVTVG (4.03 mb)
Cheminées - RAD- VTBB (4.03 mb)
Cheminées - RADVTBD (4.03 mb)