Log:
Évaluations - 4, GPA: 4.5 ( )

Instructions Vermont Casting, Modèle EWF30

Fabricant : Vermont Casting
Taille : 3.39 mb
Nom Fichier : e0c5f062-acf6-4e87-b6b3-cb5e2eb62135.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


CFM Specialty Home Products warranty will be voided by and CFM Specialty Home Products disclaims any responsibility for the following actions: • Installation of any damaged fireplace or chimney component; • Modification of fireplace, chimney assembly or any component parts thereof; (except for chase flashings as detailed in CFM Corporation Chimney Top installation instructions). • Installation other than as instructed by CFM Specialty Home Products; or • Installation and/or use of any component part not manufactured or approved by CFM Specialty Home Products in combination or assembly with a CFM Specialty Home Products fireplace system, notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory. Any such action may possibly cause a fire hazard. Consult local building codes to ensure that you are in compliance before installing the fireplace. This fireplace and chimney system must be vented to the out-of-doors. Do not obstruct or modify air inlets/outlets in any manner. Do not install combustible materials on any of the black fireplace surround. Burn only solid wood fuel. The EWF30 is intended for operation with the doors closed or fully open only with the optional spark screen in place. The doors must be in the fully closed position for clean burning operation. Do not install a solid fuel burning insert or other products not specified for use with this fireplace. This fireplace is not approved for installation in mobile homes. NOTE: Hairline cracks in hearth brick and ash lips are not a safety issue and do not need to be replaced. Drafts The fireplace should not be located in areas that create drafts (ie: frequently opened doors and central heating air inlets/outlets) that hamper the normal flow of air into the fire. EWF30 Listed UL 127 / ULC-S610 Standard for Factory Built Fireplaces Unit: WFE05H0 4 Vermont Castings EWF30 20008662 Specifications Range of heat output* ............... 11,100 - 40,500 Btu/hr Maximum heat output** ....... in excess of 55,000 Btu/hr EPA emissions rating (g/h) ......................................3.5* Area heated*** .............. Up to 2,400 sq. ft. (223 sq. m) Size of wood splits ....................18” - 23” (457-584 mm) Fuel Capacity .......................................... 40lbs. (18 kg) Loading ..................................................................Front Flue size .................................................... 8” (203 mm) Fireplace weight ............................................... 350 lbs. Primary Air Control ............................................ Manual Glass panel ......................... High-temperature ceramic Flue exit position ..................................................... Top Blower rating ...............................160cfm. (115V, 60Hz) *Under specific test conditions used during EPA emissions standard testing. **This value can vary depending on how the unit is operated, and the type and moisture content of the fuel used. Figure shown is based on maximum fuel consumption obtained under laboratory conditions and on average efficiencies. ***These values are based on operation in buildingcode conforming homes under typical winter climate conditions. If your home is of nonstandard construction (e.g. unusually well insulated, not insulated, built under ground, etc.) or if you live in a more severe or more temperate climate, these figures may not apply. Since so many variables affect performance, consult your Vermont Castings’ Authorized Dealer to determine realistic expectations for your home. EWF30 EWF30 Woodburning Fireplace Fig. 1 EWF30 specifications and framing. 12” (305 mm) 26” (660 mm) 27” (686 mm) Rough Opening Width 39......” (1000 mm) 37......” (949 mm) 11” Dia. (279 mm) 5/8” (16 mm) Recessed Nailing Flange 32......” (826 mm) 37......” (949 mm) 47......" (1203 mm) 6......” (159 mm) 10” (254 mm) 43......” Outside Air (1102 mm) 64......" (1635 mm) 64......" (1635 mm) 1" (25 mm) 1“ 91” (2311 mm) 46......” (1172 mm) 5/8" (16 mm) Electrical Access 4......” (124 mm) 12......” (318 mm) 8662 EWF30 specs 3/05 25“ (635 mm) 23......” (597 mm) 12......" (318 mm) 12” (305 mm) An optional Gravity Vent Kit is available for installation on top of the fireplace as a means to provide additional heat to the room the fireplace is in or an adjacent room. Installation instructions are provided with the Gravity Vent Kit if using this option. 5 Vermont Castings EWF30 20008662 FP1561 EWF30 parts id 3/05 Fig. 2 Fireplace and chase parts identification. FP1561 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. Termination Cap Storm Collar Pan Flashing Draftstop Batt Insulation (cut out around firestop) Firestop Ceiling Level Standoff Metal Safety Strips (1,2 or 3 pieces) Batt Insulation MUST be used in the Chase. Electrical Access Andiron Brick Ledge Vermont Castings EWF30 Chimney Requirements - Offset Installations CHIMNEY F...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories