Log:
Évaluations - , GPA: ( )

Instructions Lennox Hearth, Modèle MERIT PLUS MPDT-3328CNM-B

Fabricant : Lennox Hearth
Taille : 5.23 mb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


Instr. #750109M) 17M53 SV4.5HGS-12 Termination Guard, Horizontal Square (12 pack) (Ref. Instr. #750109M) 87L02 SV4.5HGS Termination Guard for Horizontal Square Termination (Deluxe) (1 pack) (Ref. Instr. #750055M) H5820 SV4.5HTSK Termination Shroud (Guard) for Horizontal Square Termination (1 pack) (Ref. Instr. #750246M) H3907 SV4.5ARSA Attic Insulation Shield w/ adjustable height, 12"-22" H1988 CTSA-33 Chase Top Shroud Kit, Arch Top 3 X 3 Ft., (Ref. Instr. #750194M) H1985 CTSO-33 Chase Top Shroud Kit, Open Top 3 X 3 Ft., (Ref. Instr. #750193M) H1987 CTSO-44 Chase Top Shroud Kit, Open Top 4 X 4 Ft., (Ref. Instr. #750193M) H1986 CTSO-46 Chase Top Shroud Kit, Open Top 4 X 6 Ft., (Ref. Instr. #750193M) Vent Sections (Rigid) Sealant *Only for use with MPDT/R-3328 and MPD-3530 models. 37 LENNOX HEARTH PRODUCTS • MERIT® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Listed Secure Flex™ Components Cat. # Model Description H1969 SF4.5HT-2 Horizontal Square Termination for flex (without flex vent) 77L87 SFKIT12S Square Term. for flex (with 12 inch [305 mm] compressed flex vent**) 77L88 SFKIT18S Square Term. for flex (with 18 inch [457 mm] compressed flex vent**) 77L89 SFKIT24S Square Term. for flex (with 24 inch [610 mm] compressed flex vent**) 77L90 SFKIT36S Square Term. for flex (with 36 inch [914 mm] compressed flex vent**) 77L91 SFKIT48S Square Term. for flex (with 48 inch [1219 mm] compressed flex vent**) 94L04* SFKIT12SS Small Square Termination for flex, with 12 in. (305 mm) of compressed flex vent** (Ref. Instr. #750204M) 94L05* SFKIT18SS Small Square Termination for flex, with 18 in. (457 mm) of compressed flex vent** (Ref. Instr. #750204M) 94L06* SFKIT24SS Small Square Termination for flex, with 24 in. (610 mm) of compressed flex vent** (Ref. Instr. #750204M) 94L07* SFKIT36SS Small Square Termination for flex, with 36 in. (914 mm) of compressed flex vent** (Ref. Instr. #750204M) 94L08* SFKIT48SS Small Square Termination for flex, with 48 in. (1219 mm) of compressed flex vent** (Ref. Instr. #750204M) 94L09* SF-HTSS Horizontal Small Square Termination for flex, without flex vent (Ref. Instr. #750204M) INSTALLATION ACCESSORIES CONTINUED *Only for use with MPDT/R-3328 and MPD-3530 models. **All compressed flex vents can be expanded up to two times. Listed Secure Flex™ Components Cat. # Model Description These termination kits include firestop/spacer, gear clamps and flex adaptor. 60L10 SF-18 18 feet (5.49 m) * compressed flex (Ref. Instr. #750053M) 98K03 SF-12 12 feet (3.66 m)* compressed flex (Ref. Instr. #750052M) H2248 SF4.5HF-10 Firestop / Spacer - Horizontal, flex (3-1-1 spacing), 10 Pack H2249 SF4.5VF-10 Firestop/Spacer-Vertical, flex (1-1-1 spacing), 10 Pk 56L74 SFVT30 Vertical Termination for flex (flat to 6/12) with flex adaptor, section of rigid vent, roof support collar assembly, roof flashing and storm collar. (Ref. Instr. #750052M) 56L75 SFVT45 Vertical Termination for flex (6/12 to 12/12) with flex adaptor, section of rigid vent, roof support collar assembly, roof flashing, and storm collar. (Ref. Instr. #750052M) 91L66 SFGC4-6 Gear Clamp 4.5 in. (114 mm) for flex (6 pack) 91L67 SFGC7-6 Gear Clamp 7.5 in. (190.5 mm) for flex (6 pack) H7748 H7748 36" Flex Connector Kit. 36" of flex with two adapters for mating two rigid sections of vent together. LENNOX HEARTH PRODUCTS • MERIT LENNOX HEARTH PRODUCTS • MERIT PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manu facturer’s instructions supplied with the kit.The qualified service agency performing this installation assumes responsibility for this conversion. AVERTISSEMENT Cette trousse de conversion doit etre installee par un technicien agree, selon les instructions du fabricant et selon toutes les exigences et tous les codes pertinents de l’autorite competente. Assurez vous de bien suivre les instructions dans cette notice pour reduire au minimum le risque d’incendie,d’explosionoulaproductiondemonoxydedecarbonepouvant causer des dommages materiels, des blessures ou la mort. Le tecnicien agreeestresponsabledel’installationdecettetrousse.L’installationn’est pas adequate ni complete tant que le bon fonctionnement de l’appareil convertin’apaseteverifieselonlesinstructionsdufabricantfourniesavec la trousse. Le fournisseur de service qualifie ...

Ce manuel est également adapté pour les modèles :
Cheminées - MERIT PLUS MPDT-3328CNE-B (5.23 mb)
Cheminées - MERIT PLUS MPDT-3328CPE-B (5.23 mb)
Cheminées - MERIT PLUS MPDT-332PM-B (5.23 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories