|
Facilité d'utilisation
Use a non-abrasive cleaner and NEVER clean the glass while it is hot. AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue flame or close for a more yellow flame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. This adjustment is performed by the gas fitter. Minimum Air Shutter Opening: 5/16" Natural Gas 3/8" Propane CAUTION: Carbon will be produced if air shutter is closed too much. Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Adjustment Wire: Push to close or pull to open aeration cap. Closed - Tall yellow Open - Short Blue Note: Aeration Adjustment should only be performed by an authorized Excalibur® Installer at the time of installation or service. Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace 35 Copy of the Lighting Plate Instructions NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance. Blower: Excalibur® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control. Burner Tray: The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes. Blower Thermodisc: When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal. Pilot Flame: While the pilot fl ame is on it can make a very slight "whisper" sound. Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve. Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process. OPERATING INSTRUCTIONS Gas Inlet OFF Gas Inlet MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner. The glass should be cleaned when it starts looking cloudy. 3) The heater is finished in a heat resistant paint and should only be refi nished with heat resistant paint. Excalibur® uses StoveBright Paint - Metallic Black #6309. 4) Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person. 5) The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed. Note: Never operate the appliance without the glass properly secured in place. 6) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 7) In the event this appliance has been serviced check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions. 2) Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather. 4) Inspect joints, to verify that no pipe sections or fittings have been distu...
Ce manuel est également adapté pour les modèles :Cheminées - P95-LP3 (5.06 mb)
Cheminées - P95-LP3 (5.06 mb)
Cheminées - P95-NG3 (5.06 mb)