Instructions Dansons Group, Modèle IPP Bay View Insert / Built-In

Fabricant : Dansons Group
Taille : 2.18 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


4. Adjust the FUEL RATE and the FAN SPEED to your desired settings you require upon completion of startup sequence. 1. Push firmly on the FEED RATE or START touch pad. -The COMBUSTION FAN (exhaust) will start and operate at full speed for 60 seconds, then adjust downward to match feed rate #1 -The CONVECTION FAN (heating) will start and the LED will go solid on LOW setting -The AUGER CYCLE LED will go solid for 3 seconds, indicating signal being sent to auger motor. -The IGNITER LED will light up solid and the 300 watt igniter will begin to operate. 2. On a primed AUGER system pellets will begin to fall into the BURN GRATE, and the AUTO SELF IGNITER will automatically ignite the pellets in approx. 3 – 5 min. Note: If stoves fails to light within 15 minutes, shut off the stove, remove the pellets from the burn grate and repeat step 2. If stove fails to ignite a second time, disconnect and contact your dealer. 3. Adjust the FUEL RATE and the FAN SPEED to your desired settings you require upon completion of startup sequence. NOTE: If the fire does not start, your stove will continue to feed pellets and the fans will run for approximately 15 minutes. The stove will then automatically shut off. If this happens, some unburned pellets will build up in the burn grate. To restart the fire, clean the excess pellets out of the burn grate and follow the above "Lighting a Fire". NOTE: Some odors may be given off a new stove during the initial few hours of burning while the stove and the paint are being cured. These odors are not harmful. However, ventilating the room until the odors disappear is strongly recommended. CAUTION: Never use liquid or volatile fire starters to start a fire in your stove! Do not install or operate your stove in any room where any liquid or volatile fuels or any other highly combustible items are in the air or stored in the room. These could cause a safety hazard. Canadian Comfort Industries V04 23 PELPRO OWNERS MANUAL Copyright 2004 Dansons Group Inc. Canadian Comfort Industries V04 24 PELPRO OWNERS MANUAL Copyright 2004 Dansons Group Inc. THE CONTROLS Basic Overview The AcuTron II or III digital control board was designed to give you flexibility on how you want to operate your stove. The AcuTron can be operated as a MANUAL control or by a THERMOSTAT. When operating in the Thermostat option, you can also choose to run your appliance in the ON/OFF mode or the LOW/HIGH mode. The START or FEED RATE touch pad allows electricity to flow to your stove's electrical components for 15 minutes. If after 15 minutes your stove has heated to normal operating temperatures your stove will continue to run. If the fire does not light and/or burn properly, the electricity to your stove's components will be shut off at the end of 15 minutes. The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat exchange tubes and back into the room. When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa versa. To achieve optimum heat transfer it is recommended to set the FAN SPEED to LOW when running the FEED RATE at 1 or 2, and Fan on MED on FEED RATE #3 or 4. When the START / FEED RATE is ON, the AUGER CYCLE LED will turn on when the auger is active. When the OFF touch pad is pushed [OFF], the auger motor will not run, fuel stops feeding and the fire will die. The FEED RATE works in a synchronized manner setting both the fuel rate and combustion air at the same time. When fuel is increased by setting the FEED RATE higher, combustion air is automatically increased and visa versa. HOW THE BOARD WORKS INITIAL START OR SET-UP (MANUAL OR NON-THERMOSTAT MODE) Upon initial start-up the control will feed automatically at the #1 feed rate. Press the START touch pad. - Convection (heating) fan will start and the FAN LED will be solid on LOW setting - The 300 watt Auto-Igniter will begin to glow and the IGNITER LED will be solid - The AUGER CYCLE LED will go solid for 3 seconds, indicating signal is being sent to the auger motor. - The Combustion (exhaust) fan will start and operate at full speed for 60 seconds, then adjust downward to match feed rate #1. Press FEED RATE touch pad to select desired heat output that you require upon completion of ignition sequence. NOTE: If you do not press the FEED RATE touch pad, the stove will continue to run at FEED RATE #1 and the LED will continue to flash at a fast rate. When the FEED RATE LED is flashing at a FAST rate this indicates that the LOW LIMIT (L120) is closed. This means the unit has not reached operating temperature. When the FEED RATE LED is flashing at a SLOW rate this indicates that the LOW LIMIT (L120) is open. This means the control board has entered a 5 minute “Safety Delay” mode. After the 5 minute Safety Delay is complete - IGNITER and INGNITER LED will turn off - FEED RATE LED will become solid and the appliance will feed fuel at your selected heat output RE-S...

Ce manuel est également adapté pour les modèles :
Cheminées - FPP Freestanding (2.18 mb)
Cheminées - FPP, IPP (2.18 mb)
Cheminées - IPP, FPP (2.18 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories