Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas. • If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty. Page 4 22618-17-0308 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination with the exhaust vent terminal for the horizontally vented gas is less than seven (7) feet above finished grade in the area of fueled heating appliance or equipment. The sign shall read, the venting, including but not limited to decks and porches, the in print size no less than one-half (1/2) inch in size, “GAS following requirements shall be satisfied: VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 1. INSTALLATIONOFCARBONMONOXIDEDETECTORS. At the time of installation of the side wall horizontal vented 4. INSPECTION. The state or local gas inspector of the side gas fueled equipment, the installing plumber or gas fitter shall wall horizontally vented gas fueled equipment shall not observe that a hard wired carbon monoxide detector with an approve the installation unless, upon inspection, the inspector alarm and battery back-up is installed on the floor level where observes carbon monoxide detectors and signage installed the gas equipment is to be installed. In addition, the installing in accordance with the provisions of 248 CMR 5.08(2)(a) 1 plumber or gas fitter shall observe that a battery operated through 4. or hard wired carbon monoxide detector with an alarm is (b) EXEMPTIONS: The following equipment is exempt installed on each additional level of the dwelling, building or from 248 CMR 5.08(2)(a)1 through 4: structure served by the side wall horizontal vented gas fueled 1. The equipment listed in Chapter 10 entitled equipment. It shall be the responsibility of the property owner “Equipment Not Required To Be Vented” in the to secure the services of qualified licensed professionals for most current edition of NFPA 54 as adopted by the the installation of hard wired carbon monoxide detectors Board; and a. In the event that the side wall horizontally vented gas 2. Product Approved side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, fueled equipment installed in a room or structure the hard wired carbon monoxide detector with alarm and separate from the dwelling, building or structure battery back-up may be installed on the next adjacent used in whole or in part for residential purposes. floor level. (d) MANUFACTURER REQUIREMENTS -GAS b. In the event that the requirements of this subdivision can EQUIPMENT VENTING SYSTEM NOT PROVIDED. not be met at the time of completion of installation, the When the manufacturer of a Product Approved side owner shall have a period of thirty (30) days to comply wall horizontally vented gas fueled equipment does not with the above requirements; provided, however, that provide the parts for venting the flue gases, but identifies during said thirty (30) day period, a battery operated “special venting systems”, the following requirements carbon monoxide detector with an alarm shall be shall be satisfied by the manufacturer: installed. 1. The referenced “special venting system” instructions shall be included with the appliance or equipment 2. APPROVED CARBON MONOXIDE DETECTORS. Each installation instructions; and carbon monoxide detector as required in accordance with the 2. The “special venting systems” shall be Product above provisions shall comply with NFPA 720 and be ANSI/ Approved by the Board, and the instructions for UL 2034 listed and IAS certified. that system shall include a parts list and detailed installation instruction. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. 22618-17-0308 Page 5 GAS SUPPLY Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length ...
Ce manuel est également adapté pour les modèles :Cheminées - BP)-1 (4.33 mb)
Cheminées - GN (4.33 mb)
Cheminées - GP)-1 (4.33 mb)
Cheminées - PV-28SV50-BN (4.33 mb)