|
Facilité d'utilisation
This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect. The use of the following gas connectors is recommended: — ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings — ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length. Figure 3 20101-0-0306 Page 9 GAS SUPPLY (continued) Checking Manifold Pressure VFP(32,36)FP(30,31)LN (Natural gas) will have a manifold pressureofapproximately3.5"w.c.(.871kPa)formaximuminputor 1.7"w.c.(.423kPa)forminimuminputatthepressureregulatoroutlet with the inlet pressure to the pressure regulator from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.614kPa). VFP(32,36)FP(20,21)LN (Natural gas) will have a manifold pressure of approximately 6.0" w.c. (1.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 7.0" w.c. (1.74kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa). VFP(32,36)FP(30,31)LP (Propane gas) will have a manifoldpressureapproximately10.0"w.c.(2.49kPa)formaximum input or 4.9"w.c. (1.220kPa) for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa). VFP(32,36)FP(20,21)LP (Propane gas) will have a manifold pressure approximately 10.0"w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa). Atest gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch (3mm) N.P.T. plugged tapping. VFP(32,36)FP(30,31) Millivolt Control The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “A” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks. CLEARANCES Minimum Wall and Ceiling Clearances (Figure 4) Mantel Clearances (Figure 5) Sidewall Clearances: The clearance from the inside of the fireplace to any combustible wall should not be less than 2". Fireplace Side and Back Clearances: The fireplace outer casing sides and back have zero clearance to combustibles. Ceiling Clearances: The ceiling height should not be less than 36" from the top of the hood. Mantel Clearances: Vent free fireplace models must use the hood supplied with the fireplace. If a combustible mantel is installed, it must meet the clearance requirements detailed above. 2” 36” COMBUSTIBLESALLOWEDMANTELHOOD2” 7” 4” 93/4” 41/4” 6” 12.” 8” 151/4” 18” 10” 12” Figure 5 Figure 4 Page 10 20101-0-0306 20101-0-0306 Page 11 Do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 6 No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles. Figure 7 COMBUSTIBLE MATERIALS Page 12 20101-0-0306 JUNCTION BOX ASSEMBLY C Figure 8 VFP32FP VFP36FP A 34" 39" B 29" 34" C 17 3/8" 17 3/8" D 31" 36" E 22 7/8" 24 7/8" F 32 3/4" 34 3/4" G 44 7/16" 48" H 44 7/16" 48" I 55 7/8" 60 7/8" J 35 3/4" 37 3/4" FIREPLACE DIMENSIONS INSTALLING HOOD AND TRIM KIT A black hood and trim kit is furnished with each model VFP(32,36)FP fireplace. The hood MUST be installed before the fireplace is used. Failure to do so may create a possible fire hazard. Attention: The hood is located behind top louver during shipment of fireplace. Remove top louver for access to hood. The trim kit is used to finish the fireplace. The trim kit is used in place of brick, marble or other finishing material. 1. To remove top louver, lift louver and pull forward. 2. Open bottom louver. 3. Insert trim side left and trim side right into the fireplace. Attach (4) Phillips screws through bottom and top clearance hole on trim side left and trim side right and into fireplace. 4. Insert flange on fireplace hood on the top of the firebox in the gap between the louver and firebox top. 5. Attach fireplace hood to fireplace with (3) Phillips screws. See Figure 9. 6. Insert the trim top into the top, interior of the fireplace. Position the (3) clearance holes in the trim top downward. Align the (3) clearance holes with the (3) screw holes in the top, interior of the fireplace. When the trim top contacts the wall s...
Ce manuel est également adapté pour les modèles :Cheminées - 31)L(N (1.87 mb)
Cheminées - VFP32FP (1.87 mb)
Cheminées - 21)L(N (1.87 mb)
Cheminées - VFP36FP (1.87 mb)