|
Facilité d'utilisation
The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with the kit. Installer notice: Using an ink pen, fill out the required information on the conversion label. Remove the backing from label and stick label in a visible position on bottom of fireplace close to gas valve. Installer notice: These instructions must be left with the appliance. Instructions for converting your direct ignition fireplace from natural gas to propane/LP gas. All direct ignition fireplaces are shipped from the factory equipped to operate on natural gas. To convert the direct ignition fireplace to operate on propane/LP gas, follow the instructions on Page 43. Please see the appropriate parts list for your model for parts included with the direct ignition fireplace. Check the items in the kit with the parts list. Notify the supplier of any items that are missing before installing the conversion kit. Page 42 23552-1-0607 23552-1-0607 Page 43 1. Turn off the gas supply. 2. Turn off the electrical supply to the appliance if so equipped. 3. Remove top louver and lower bottom louver. 4. Remove glass frame assembly. 5. Remove logs from burner assembly. VALVE CONVERSION 6. Remove plastic cap from regulator fitting. Unscrew fitting using a 7/16" wrench. Turn fitting over so end of fitting marked "LPG" (red) screws into valve. Tighten fitting (snug only). Replace plastic cap. 7. Remove 1/4" screw from air shutter. 8. Located to the right of electrodes is a burner hold-down tab. Using needle-nose pliers, bend burner hold-down tab off the main burner. 9. Remove main burner by pivoting main burner forward as you slide main burner from left to right. Be careful as you remove main burner in order to protect the electrodes from being damaged. 10. Remove air shutter from orifice fitting. 11. Remove natural gas main burner orifice from orifice fitting. 12. Install propane/LP main burner orifice marked #56 for DVD32FP50, marked #55 for DVD36FP50, marked 1.45 mm for DVD42FP50 or marked #52 for DVD48FP50. Important: Failure to install the correct orifice will result in unit over-firing that could overheat the appliance and result in a fire. 13. Replace air shutter onto orifice fitting. Air shutter must be threaded and bottomed-out onto orifice fitting. 14. Replace main burner onto burner assembly. Place main burner beneath electrodes, slide main burner from right to left into burner location, and pivot main burner away from you and into air shutter. 15. Set air shutter opening at 1/4" for DVD32 or DVD36 and 5/16" for DVD42 or DVD48. Tighten air shutter in place with 1/4" screw from step 7. 16. Using needle-nose pliers, bend burner hold-down tab over main burner. 17. Refer to log placement, pages 33 and 34 to place logs onto burner assembly. 18. Loosen screw and attach a manometer or pressure gauge to the outlet pressure tap of the control valve. 19. Turn on the gas supply. Turn on the electrical supply to the appliance. Check for gas leaks using soap and water solution or leak detection solution. Bubbles indicate a leak that MUST be corrected. Do not use an open flame to test for gas leaks. 20. Check the air shutter opening. See chart and illustration below. 21. Relight the main burners and verify proper burner ignition and operation. 22. With the main burner burning, read the pressure on the manometer or pressure gauge. The pressure on the gauge should read between 9.8" and 10.2" w.c. 23. Turn off the gas supply. Turn off the electrical supply to the appliance. 24. Remove the manometer or pressure gauge. Tighten the screw in the pressure tap. 25. Turn on the gas supply. Turn on the electrical supply to the appliance. 26. Immediately test all gas line connections and the control valve for gas leaks using a soap and water solution or other gas detection solution. Bubbles indicate a leak that MUST be corrected. Do not use an open flame to test for gas leaks. 27. Using a ball point pen, fill out the conversion label that is supplied with the conversion kit. Place the conversion label adjacent to the rating plate. 28. Replace glass frame assembly. 29. Reinstall top and bottom louvers. 30. Test operation of fireplace once again. Allow the fireplace to operate for at least 10 minutes and check flame coloration. Flames on rear of burner should be yellow without any orange-colored tip. Minor adjustment of the air shutter may be necessary to "tune in" the proper flame color. Model AIR SHUTTER SETTINGS BURNER ORIFICE Opening "A" Propane/LP Orifice DVD32 1/4" (6.4 mm) #56 DVD36 1/4" (6.4 mm) #55 DVD42 5/16" (7.9 mm) 1.45 mm DVD48 5/16" (7.9 mm) #52 “A” REGULATOR FITTING NOTE: STAMPED WITH GAS TYPE SET FOR USE Maxitrol Valve Conversion Figure 59 Figure 60 DIRECT IGNITION PROPANE/LP GAS CONVERSION MAINTENANCE AND SERVICE PLEASE NOTE It is normal for appliances fabricated of steel...
Ce manuel est également adapté pour les modèles :Cheminées - DVD36FP3 (3.9 mb)
Cheminées - DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 (3.9 mb)
Cheminées - DVD42FP3 (3.9 mb)
Cheminées - DVD42FP5 (3.9 mb)