Log:
Évaluations - 2, GPA: 4 ( )

Instructions Hearth and Home Technologies, Modèle 823-0290

Fabricant : Hearth and Home Technologies
Taille : 2.44 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This is a naturally clean portion of the burn. The coals burn with hot blue flames. It is very important to reload your stove while enough lively hot coals remain in order to provide the amount of heat needed to dry and rekindle the next load of wood. It is best to open the air controls for a short while before reloading. This livens up the coalbed. Open door slowly so that ash or smoke does not exit stove through opening. You should also break up any large chunks and distribute the coals so that the new wood is laid on hot coals. Air quality is important to all of us, and if we choose to use wood to heat our homes we should do so responsibly. To do this we need to learn to burn our stoves in the cleanest way possible. Doing this will allow us to continue using our wood stoves for many years to come. AIR CONTROLS START-UP AIR SYSTEM The combustion air enters at the rear of the firebox through the rear air tubes. This air supply is controlled by the Startup Air Control. For more air push control in, for less air pull control out. PRIMARY AIR SYSTEM The primary air enters below the ash catcher and is directed to the upper front of the firebox, near the top of the glass door and to the lower front of firebox. This preheated air supplies the necessary fresh oxygen to mix with the unburned gases, helping to create secondary, tertiary and quaternary combustions. This air is regulated by the Primary Air Slide Control. For more primary air slide control left, for less air, slide control to the right. Primary Air Slide Control Start-Up Air Control Figure 19A Primary Slide Control Start-Up Control OPEN -SLIDE LEFT OPEN - PUSH IN CLOSE -SLIDE RIGHT CLOSED - PULL OUT September 1, 2008 250-5763C Page 19 RR Isle Royale Wood Stove OPERATING INSTRUCTIONS (Cont’d) HEAT OUTPUT SETTINGS for maximum operating efficiency with the lowest emissions, follow these operating procedures: 1. Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for 5 to 15 minutes. 2. Regulate burn rate (heat output) by using the Primary Air Slide Control (center under ashcatcher). The Start-Up Air Control (on the right) is used for initial start-up and reloading. 3. Heat output settings are listed below, following 5 to 15 minutes of burning with controls wide open (see #1 above): 4. Burn dry, well-seasoned wood. BTU / Hr Start-Up Air Control *Primary Air Slide Control Below 10,000 Closed after 5 to 15 minutes Slide to right10,000 - 15,000 Closed after 5 to 15 minutes 1/8 to 1/2" open (slide to left) 15,000 - 40,000 Closed after 5 to 15 minutes 1/2” to 1-1/8" open (slide to left) Maximum Heat Closed after 5 to 15 minutes Fully open (all the way left WARNING: Do not operate with Start-Up Air Control in the open positionin excess of 15 minutes! Risk of extreme temperatures! Prolonged operation of this stove with the Start- Up Air Control in the open position may cause the combustible materials around the stove to exceed safe temperature limits. NOTE: These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this operation information is a guideline only. Similar burn rates may be obtained using other settings unique to your situation. OPERATING THE TOP LOADING OPTION NOTE: This stove is provided with 3 fiber door handles for the door, baffle by-pass handle and the top-loading griddle slot. CAUTION! SHIPPING BOLTS MUST BE REMOVED PRIOR TO REMOVING GRIDDLE. 1. Using a 7/16 wrench, remove the 2 shipping bolts underneath the griddle before lifting the griddle off of stove. 2. Open by-pass door by moving the side handle towards rear of stove. 3. Wait 15 seconds to allow smoke to clear out of firebox. 4. Slowly open top loading door and load unit with fuel. 5. Close the top door. 6. Close the by-pass door (move side handle towards front of stove.) NOTE: See page 21 for operation considerations with a blower installed. CAUTION! IF THE DOOR HANDLE IS LEFT ON THE STOVE DURING OPERATION, IT MAY OVERHEAT AND CAUSE BURNS TO YOUR HAND, EITHER REMOVE THE HANDLE DURING OPERATION, OR WEAR PROTECTIVE GLOVES. ALSO, USE CARE WHEN OPERATING THE DRAFT CONTROL KNOBS AS THEY ALSO BECOME HOT DURING OPERATION. WARNING! ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED ExCEPT DURING START-UP AND RE-FUELING OR WHEN USING THE FIRESCREEN. Page 20 250-5763C September 1, 2008 Isle Royale Wood Stove R OPERATING INSTRUCTIONS (Cont’d) caution: before lighting your first fire in the stove: 1) make certain that the baffle is correctly positioned. It should be resting against the rear support; 2) Follow instructions on page 22 for cleaning plated surfaces, and; 3) Remove all labels from glass.front. caution: never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use. BUILDING A FIRE There a...

Ce manuel est également adapté pour les modèles :
Cheminées - 823-0170 (2.44 mb)
électrique - Isle Royale (2.44 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories