Log:
Évaluations - 2, GPA: 4 ( )

Instructions Majestic Appliances, Modèle 360DVSR

Fabricant : Majestic Appliances
Taille : 2.98 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Of 14mv • Valve Is Turned On • Wall Switch Is Not Turned On. Watch For Grounded Wires! • Thermopile Needs A Min. 325mv. • Plugged Burner Orifice • Defective Valve. Turn To Pilot, Meter Should Read Greater Than 100mv. If Not, Replace. 32 10006326 360DVS Series Direct Vent Fireplaces Fuel Conversion Instructions To convert this appliance from gas type to another, follow these instructions. Before proceeding, turn control knob to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be HOT! Allow to cool before proceeding. This conversion procedure must be carried out by an authorized service provider. 1. Disconnect power to unit and shut off the gas supply. 2. Remove window frame assembly (see “Window Frame Assembly Removal” Section). 3. Carefully remove the logs and lava rock material. 4. Remove the screws holding the burner housing assembly in place. 5. Remove the burner housing assembly. On some models you may need to loosen the pilot bracket retaining screw/nut, and tilt the pilot and bracket assembly to gain sufficient clearance to remove the burner housing assembly. 6. Remove front and rear orifice and replace with orifice supplied in the conversion kit. NOTE: On 360DV/S2/S3/SL/SR, both burner orifices are the same size. 7. Remove the screws holding the air shutter to the burner tubes. (Fig. 47) Note the alignment of the air shutter on the tubes. Remove the air caps and replace them with the new air shutters supplied in the conversion kit. Air Shutter Retain- ing Screws Air Shutters FP1447 Fig. 47 Air shutter adjustment. 8. SIT Top Convertible Pilot Gently lift off pilot hood from the pilot. NOTE: Do not remove the spring clip holding the hood in place. Using a correctly-sized Allen key, unscrew the exposed orifice. Insert the new orifice supplied in the kit; do not overtighten the orifice. Replace the pilot hood ensuring the index tab aligns with the notch on the hood. PSE Pilot Using a suitable wrench on hexagonal body, unscrew the pilot hood assembly from the pilot. Do not twist the hood itself. Remove the orifice and replace it with the new orifice supplied in the kit. Refit the pilot hood assembly. Do not overtighten the pilot hood. The hood must return to its original alignment. Take care not to damage the thermocouple, thermopile or igniter. 9. SIT 820 NOVA Gas Control Valve (Fig. 48) a) Using a Torx T20 or slotted screwdriver, remove and save three (3) pressure regulator mounting screws (A), pressure regulator tower (B), and diaphragm (C). b) Ensure the rubber gasket (D) is properly posi tioned and install the new HI/LO pressure regulator to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Reference torque: 25 in.lb.) c) Install the enclosed identification label (F) to the valve body where it can be easily seen. A B C OFFPILOT ON FC107 Fig. 48 Remove mounting screws, pressure regulator tower and diaphragm assembly. 10006326 33 360 DVS Series Direct Vent Fireplaces D E F OFFPILOT ON FC108 Fig. 49 Replace regulator. Honeywell Gas Control Valve (Fig. 50) The Honeywell valve fitted to this unit is suitable for use with LP or Natural Gas. It is converted to the required gas application by installing a color-coded conversion screw. a) Using a suitable small screwdriver, lift out the central regulator cap from the “HI/LO” knob on the valve. b) Unscrew the exposed conversion screw. c) Insert the new color coded conversion screw. Do not overtighten the screw; it must be finger- tight. d) Refit the regulator cap. e) Mount conversion label supplied with the conversion screw to the valve in a visible position. LOHIRegulator Cap Conversion Screw Pressure Regu- lator Housing HV120 Fig. 50 Honeywell conversion screw replacement. 10. Reassemble fireplace in the reverse order, except for the window frame assembly. Leave this off until after unit has been checked for leaks and the gas supply has been bled. 11. After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. 12. Fire up the unit. Check for flame impingement on the logs, adjusting them as necessary. 13. Check manifold and supply pressures against the appliance specifications. The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variations are in orifice sizes and component part numbers. Your authorized service provider will ensure correct parts are used. 34 10006326 360DVS Series Direct Vent Fireplaces Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use. FK24/FK12 Fan Assembly The fan unit requires periodic cleaning. At le...

Ce manuel est également adapté pour les modèles :
Cheminées - 360DVS2 (2.98 mb)
Cheminées - 360DVS3 (2.98 mb)
Cheminées - 360DVSL (2.98 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories