Log:
Évaluations - 5, GPA: 3.4 ( )

Instructions Stovax, Modèle Chamonix & Aspen (P)8136**UC

Fabricant : Stovax
Taille : 602.53 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Any damper plates should be removed or secured in the fully open position, and no restrictor plates should be fitted. 1.4 The chimney should be swept prior to the installation of the appliance - unless it can be seen to be clean and unobstructed throughout its entire length. 1.5 Ensure that there is a smooth tapered transition from the fireplace opening into the chimney or flue. 1.6 The flue pull should be checked prior to installation of the appliance. Apply a smoke pellet to the flue or chimney opening and ensure that the smoke is drawn into the opening. If there is not a definite flow, pre-heat the chimney for a few minutes and re-test the flow. IF THERE IS STILL NO DEFINITE FLOW, THE CHIMNEY MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE. 2. INSTALLATION OF THE GAS SUPPLY 2.1 Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. 2.2 Ensure that the gas supply is capable of delivering the required amount of gas, and is in accordance with the rules in force. 2.3 Soft copper tubing and soft soldered joints can be used, but must not be closer than 50mm (2") to the base of the tray. 2.4 A means of isolating the gas supply to the appliance must be provided independent of any appliance control. 2.5 All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance. 3. VENTILATION It is important to ensure that any national ventilation requirements are taken into account during the installation of this appliance. 3.1 This appliance requires an air vent of at least 100cm2 effective area. 3.2 It is essential to check for flue clearance, see installation section 6, Commissioning. If spillage is detected, it may be necessary to provide additional ventilation. 3.3 The ventilation is in addition to any openable window, and although it must communicate with the outside air, wherever possible, it can communicate with an adjacent room provided that the space has a similar vent to the outside. 13 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 4. APPLIANCE LOCATION 4.1 This appliance must stand on a non-combustible hearth that is at least 12mm thick. 4.2 It must be fitted into a non-combustible opening. 4.3 These appliances must be hearth mounted into a fireplace opening conforming to National Standards. 4.4 The appliance must be firmly fixed to the hearth. 4.5 Ensure that no naked flame or incandescent part of the fire bed projects beyond the vertical plane of the fireplace opening. 4.6 The appliance must not be installed in any room that contains a bath or shower. 4.7 Ensure clearances to combustible materials. See diagram 2. 4.8 The following table indicates the minimum opening sizes for each model. In each case, a gap of 20mm has been allowed to both Left and Right of the basket. See diagram 3. 3 MODEL WIDTH DEPTH SMALL ASPEN SMALL CHAMONIX 640mm 400mm MEDIUM CHAMONIX 690mm 350mm LARGE ASPEN LARGE CHAMONIX 790mm 500mm TAHOE 670mm 300mm 5. CONTROL UPGRADE 5.1 This appliance is supplied with a control valve that can be easily upgraded to battery powered remote control. This upgrade can be fitted by anyone capable of simple DIY jobs and requires no special training. This upgrade can be obtained through your local GAZCO stockist. 5.2 STANDARD REMOTE CONTROL This remote control can control the fire after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning. GAZCO PART NUMBER 8455. 14 INSTALLATION INSTRUCTIONS INSTALLATION IMPORTANT:ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS AT THE FRONT OF THE BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SERVICING SECTION 9. 1. SAFETY PRECAUTIONS 1.1 This appliance must be installed in accordance with the rules in force, and used only in a sufficiently ventilated space. Please read these instructions before installation and use of this appliance. 1.2 These instructions must be left intact with the user. 1.3 Do not attempt to burn rubbish on this appliance. 1.4 In your own interest, and those of safety, this appliance must be installed by competent persons in accordance with local and national codes of practice. Failure to install the appliance correctly could lead to prosecution. 1.5 Keep all plastic bags away from young children. 2. UNPACKING 2.1 Remove the appliance from its packaging, and check that it is complete and undamaged. 2.2 Put the loose ceramic parts to one side so that they are not damaged during installation. 3. INSTALLATION These fires have preset High and Low settings with a Gas working pressure as listed below. 20mb on Natural Gas, 29mb on Butane and 37mb on Propane with the fire on full. 3.1 Ensure the minimum opening dimensions are correct, place the decorative basket in the open...

Ce manuel est également adapté pour les modèles :
Cheminées - Chamonix & Aspen (P)8119**UC (602.53 kb)
Cheminées - Chamonix & Aspen (P)8120**UC (602.53 kb)
Cheminées - Chamonix & Aspen (P)8127**UC (602.53 kb)
Cheminées - Chamonix & Aspen (P)8128**UC (602.53 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories