|
Facilité d'utilisation
This makes the front of fireplace flush with wall. An optional trim kit accessory is available (see Accessories, page 30). Trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace you must follow the clearances shown in Figure 11, page 12. Follow the instructions below to install the fireplace in this manner. Actual Framing Height 26" 26 7/8" Front Width 26 3/4" 26 7/8" Depth 9 1/2" 10 1/2" Bottom 3/4" 3/4" 1. Frame in rough opening. Use dimensions shown in Figure 8, page 11, for the rough opening. If installing in a corner, use dimensions shown in Figure 9, page 11, for the rough opening. The height is 26 7/8" which is the same as the wall opening above. 113111-01A INSTALLATION Continued WARNING: If pre-wiring, do not connect wiring to any electrical source at this time. Install fireplace electrical outlet and connect wiring to outlet before connecting to electrical source. The fireplace electrical outlet is included with the GA3450T blower accessory. Only use the fireplace electrical outlet supplied with the GA3450T blower accessory. 2. If installing GA3450T blower accessory, do so at this time. See Installing Blower Accessory GA3450T, page 13. Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installation (see Accessories, page 30) Use only approved three- wire electrical wiring. Note: A qualified installer should make all electrical connections. 3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not assembled firebox, follow instructions on page 4. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Connecting to Gas Supply, page 16. 7. Bend four nailing flanges on outer casing with pliers (see Figure 10). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Connections, page 18. 10. If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim accessory for attaching trim. IMPORTANT: When finishing your firebox, combustible materials WARNING: Do not allow any combustible materials to overlap the firebox front facing. IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots. WARNING: Do not allow noncombustible materials to cover any necessary openings like louvered slots. 26 7 / 8 " 26 7 / 8 " 10 1 / 2 " 3/4" Off The Floor Minimum Figure 8 - Rough Opening for Installing in Wall 36 5 / 8 " 25 7 / 8 " 51 3 / 4 " 26 7 / 8 " Figure 9 - Rough Opening for Installing in Corner Figure 10 - Attaching Fireplace to Wall Studs Nails or Wood Screws Nailing Flanges 113111-01A INSTALLATION Continued WARNING: Never modify or cover the louvered slots on the front of the firebox. WARNING: Use only noncombustible mortar or adhesives when overlapping the front facing with noncombustible facing material. Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening. NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual. NOTICE: If your installation does not meet the minimum clearances shown in Figure 11, you must do one of the following: • raise the mantel to an acceptable height • remove the mantel OPTIONAL MANTEL INSTALLATION Note:Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. Refer to instructions on page 5 for firebox assembly. Blower accessory should be installed if it is being used (see Accessories, page 30). 1. Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside. 2. Place fireplace on wood base. 3. Place mantel around fireplace/base assembly. 4. Assemble trim kit. See Assembling Perimeter Trim, page 13. 5. Firmly snap trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12). 6. Align trim kit for flush fit around opening. 7. Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 12). 8. Remove trim kit and mantel. Be careful not to damage wall or mantel. 9. Place wood base next to wall at installation...
Ce manuel est également adapté pour les modèles :Cheminées - 000 (816.13 kb)
Cheminées - VMH26TPC, VMH26TNC (816.13 kb)