Instructions Monessen Hearth, Modèle SSDVST-CNE-B

Fabricant : Monessen Hearth
Taille : 4.94 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


NOTE: Outer pipe is pulled away to show the detail of the inner pipe. APPLY ONLY MIL-PAC BLACK HIGH TEMPERATURE SEALANT (Cat. No. 10K81) to the outside surface of both collars of the adapter (be especially careful to fill the grooves of the outer collar to be covered by the flexible pipe) and slide flexible pipe over inner and outer adapter collars. 1-3/4 inch (44 mm) flexible pipe and adaptor outer collar overlap Adapter (SV4.5RF) Attach adaptor to appliance Collar, or secure vent sections Flex Vent Gear Clamps Securing Screw - 3 places, 120° apart (equally spaced) just below gear clamp 1-3/4 in. (44 mm) flexible pipe and adaptor inner collaroverlap Securing Screw -3 places, equally spaced, just below gear clamp. Figure 41 B. Install the Outer Flex Pipe - 1. Install the large gear clamp loosely around the outer flexible vent pipe, push it back out of the way. 2. Apply a bead of Mill-Pac Black (700° F, high temperature sealant - Catalog No. 10K81) to the outer adapter collar; to the grooves of the collar which extend approximately 1 inch from the end and to the flat surface, approximately 1-3/8 inches from the end. 3. Pull and extend outer flexible vent pipe. 4. Slide the outer flex pipe over the adapter collar. Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1-3/4 inches from the end, and that it is free from damage or tears. 5. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adapter outer collar approximately 3/4 inch from the end of the flex. 6. Install three screws, 120 degrees apart, through the flexible vent pipe and into the adapter collar just below the gear clamp to provide additional security to the connection. C. Route Flex Vent - Ensure that the flex vent is properly routed to provide the required clearance. Do not allow the flexible vent to bend in a radius tighter than 5" (127 mm). Refer to Figure 42. Space out the internalflexventspacersevenly -approximately every 6 inches -and avoid kinking of inner pipe. Support horizontal sections of flex with metal straps at 2 foot (0.61 m) intervals. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. D. Install Firestop / Spacers at ceilings and walls -When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropriate sections and Figures shown throughout the venting section for their installation requirements. Flexible Vent Section Minimum 5” (127 mm) Radius Figure 42 E. Attach Flex Vent to Termination Secure Flex components can be purchased separately and attached to bulk lengths of Secure Flex flexible tubing cut to size at the job site. Secure the flexible vent to the Secure Flex terminations in the same manner (see Figure 41) as it was attached to the adapter. Note:SecureFlexventmustbeattachedtoSecure Flexterminationsonly.DONOTsubstituteSecure VentterminationsortheSecureVentadapterfor Secure Flex components. The collars of Secure Flex terminations and adapters have a different diameter than that used with the Secure Vent pipe. Additionally, Secure Flex components have an extended length center tube for use in attaching the flexible vent. Step 4. FIELD WIRING Step 4. FIELD WIRING Ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box. See Figure 46.Failureto do sowill resultin a potential safety hazard. The appliance must be electricallygroundedinaccordance withlocalcodesor,intheabsenceof local codes, the National Electrical Code, ANSI/NFPA 70 latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code). CAUTION: Label all wires prior to disconnectionwhenservicingcontrols. Wiringerrorscan cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, etiquetez tous les fils avant de les debrancher. Des erreurs de cablage peuvent entrainer un fonctionnement inadequat et dangereux. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adequatement une fois l'entretien termine. Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory on both models. A. Millivolt Wiring (See Figure 43): 1. Install and wire in the burner control switch. Install either "a" or "b" below, NOT BOTH (installingbothmayresultinimproperburner operation). a. Optional OFF/ON Switch -Install the OFF/ ONburnercontrolswitch(rocker switch) as shown in Figures 43 and 44. b. Optional Wall Switch, Wall Thermostat Or Remote Control Receiver -Install snap bushing (provided in Electrical Outlet Kit - See Figure 44) into control switch knock-out in side panel (see Figures 12 and 13 on Pages 10 and 11). Wire the optionalcontrolswitchwithinthemillivolt control circuit (as shown in Figure 43) using the 15 feet of 2 conductor wire supplied (route wires through the snap bushing to the optional control...

Ce manuel est également adapté pour les modèles :
Cheminées - SSDVPF-CNE-B (4.94 mb)
Cheminées - SSDVPF-CNE-B (4.94 mb)
Cheminées - SSDVPF-CNE-B (4.94 mb)
Cheminées - SSDVPF-CNE-B (4.94 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories