Log:
Évaluations - 5, GPA: 3.6 ( )

Instructions Heat & Glo LifeStyle, Modèle RCOR-HV-IPI

Fabricant : Heat & Glo LifeStyle
Taille : 3.11 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Venting with Two 90° Elbows H1 H V V V1 H NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) NATURAL GAS VENTING WITH TWO 90° ELBOWS V + V1 (FT.) H (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + V1 + H = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V + V1 (FT.) H (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + V1 + H = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 27 Figure 16. Venting with Two 90° Elbows Figure 17. Venting with Two 90° Elbows H1 V H V H H1 NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) NATURAL GAS VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH TWO 90° ELBOWS V (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) 28 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 Figure 18. Venting with three 90° elbows H H1 H2 V H V H1 V1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 + H2 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 + H2 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m) H + H1 + H2 = 18’ MAX. (5.5m) H + H1 + H2 = 12’ MAX. (3.6m) NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 = 50’ MAX. (15.2m) H + H1 = 18’ MAX. (5.5m) H + H1 = 12’ MAX. (3.6m) Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 29 Figure 19. Venting with three 90° elbows V H H1 V1 V H H1 V 1 NATURAL GAS VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 900 Elbow on top 2.5’ MAX. (64mm) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V+ V1 + H + H1 = 50’ MAX. (15.2m) PROPANE VENTING WITH THREE 90° ELBOWS V + V1 (FT.) H + H1 (FT.) 900 Elbow on top 2’ MAX. (610mm) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V+ V1 + H + H1 = 50’ MAX. (15.2m) H + H1 = 12’ MAX. (3.6m) H + H1 = 18’ MAX. (5.5...

Ce manuel est également adapté pour les modèles :
Cheminées - LCOR-HV-IPI (3.11 mb)
Cheminées - PIER-HV-IPI (3.11 mb)
Cheminées - ST-HV-IPI (3.11 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories