Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Superior, Modèle CFST-CMP

Fabricant : Superior
Taille : 585.54 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Bag of Rockwool/Ember Coals 125011 1 125011 1 11. Refractory Liner 903216 2 903216 2 No. Description CFST-CMN CFST-CMP Part No. Qty. Part No. Qty. 20. Gas Valve - SIT 901916 1 901917 1 21. Piezo Igniter 111061 1 111061 1 22. Orifice, Main Burners 124291 2 124292 2 23. Pilot Assembly (ODS) 901914 1 901915 1 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT 18 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10 No. No. CFPF-CMN CFPF-CMP Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3. Bar, Louver (Black) - End Panel 104955 4 104955 4 4. Hood (Black), Clean Face - Main Panel 108971 2 108971 2 5. Hood (Black), Clean Face - End Panel 124761 1 124761 1 6. Screw 000861 8 000861 8 7. Replacement Glass Panel with Gasket - Main Panel 104852 2 104852 2 8. Replacement Glass Panel with Gasket - End Panel 104853 1 104853 1 9. Door Switch 094468 1 094468 1 10. Gas Valve with Burner Assembly 123111 1 123112 1 11. Burner Assembly 123151 1 123151 1 12. Log Set (Split) – – – – a. b. c. d. e. f. g. Bottom, Front 903601 1 903601 1 Bottom, Rear 903602 1 903602 1 Log, Center 903603 1 903603 1 Twig, Left 903604 1 903604 1 Top Twig, Center 903605 1 903605 1 Top Twig, Right 903606 1 903606 1 Log, Top, Vertical 903607 1 903607 1 13. Bag of Rockwool/Ember Coals 125011 1 125011 1 14. Refractory Liner 903216 1 903216 1 No. Description CFPF-CMN CFPF-CMP Part No. Qty. Part No. Qty. 20. Gas Valve - SIT 901916 1 901917 1 21. Piezo Igniter 111061 1 111061 1 22. Orifice, Main Burners 124291 2 124292 2 23. Pilot Assembly (ODS) 901914 1 901915 1 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT 20 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 g. f. TROUBLESHOOTING GUIDE FOR UNVENTED GAS PRODUCTS TROUBLESHOOTING GUIDE FOR UNVENTED GAS PRODUCTS POSSIBLE CAUSE REMEDY 1. When igniter button is pressed, there is no spark at ODS/pilot. A. Igniter electrode positioned wrong. Replace igniter. B. Igniter electrode broken. Replace igniter. C. Igniter electrode not connected to igniter cable. Reconnect igniter cable. D. Igniter cable pinched or wet. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry. E. Piezo igniter nut is loose. Tighten nut. F. Broken igniter cable. Replace igniter cable. G. Bad piezo igniter. Replace piezo igniter. 2. Heater produces unwanted odors. A. Heater burning vapors from paint, hair spray, glues, etc. Ventilate room. Stop using odor-causing products while fireplace is running. B. Gas leak. See Warning statement on the front page. Locate and correct all leaks. 3. Heater shuts off in use (ODS operates). A. Not enough fresh air is available. Open window and/or door for ventilation. B. Low line pressure. Contact local gas company. C. ODS/pilot is partially clogged. Clean ODS/pilot. 4. Gas odor even when control knob is in “OFF” position. A. Gas leak. See Warning statement on the front page. Locate and correct all leaks (see Checking Gas Connections, page 8). B. Control valve defective. Replace control valve. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. A. Gas supply turned off or manual shut-off valve closed. Turn on gas supply or open manual shut-off valve. B. Control knob not in “PILOT” position. Turn control knob to pilot position. C. Control knob not pressed in while in “PILOT” position. Press in control knob while in pilot position. D. Air in gas lines when installed. Continue holding down control knob. Repeat igniting operation until air is removed. E. ODS/pilot is clogged. Replace ODS/pilot assembly or get it serviced. F. Gas regulator setting is not correct. Replace gas regulator. 6. ODS/pilot lights, but flame goes out when control knob is released. A. Control knob not fully pressed in. Press in control knob fully. B. Control knob not pressed in long enough. After ODS/pilot lights, keep control knob pressed in 30 seconds. C. Manual shut-off valve not fully open. Fully open manual shut-off valve. D. Thermocouple connection loose at control valve. Hand tighten until snug, then tighten ... turn more. E. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: 1). Low gas pressure 2). Dirty or partially clogged ODS/pilot 1). Contact local gas company. 2). Replace ODS/pilot assembly or get pilot serviced. F. Thermocouple damaged. Replace thermocouple. G. Control valve damaged. Replace control valve. 7. Burner does not light after ODS/pilot is lit. A. Burner orifice is clogged. Clean burner or replace burner orifice. B. Burner orifice diameter is too small. Replace burner orifice. C. Inlet gas pressure is too low. Contact local gas company. 8. Delayed ignition of burner. A. Manifold pressure is too low. Co...

Ce manuel est également adapté pour les modèles :
Cheminées - CFPF-CMN (585.54 kb)
Cheminées - CFPF-CMP (585.54 kb)
Cheminées - CFST-CMN (585.54 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories