Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Superior, Modèle DR-400CMP

Fabricant : Superior
Taille : 973.7 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The adjustment rod and associated adjustable air shutter is patented technology. Flame adjustments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minutes after each adjustment. Note: If the flame still appears anemic with the air shutter closed all the way against the stop (usually a result of lengthy vertical runs), turn the appliance off, turn the gas supply off, wait for the parts to cool, remove the glass door and logs to access the air shutter. The shutter is prevented from actually closing all the way by an adjustment set screw (see Figure 54). Remove this screw using a ... inch nut driver. Reinstall the logs and glass door, turn the gas back on and then restart the appliance. After 30 minutes, reobserve the flame. Adjust the air shutter as previously described. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob in the ON position and the remote switch OFF. Close the lower control compartment door. Adjustment Rod Up (Fully Open Position) Air Shutter Burner Tube Adjusting Set Screw Adjustment Rod Down (minimum air opening position) FACTORY AIR SHUTTER SETTING Natural Gas Propane Gas Models inches inches (mm) (mm) DT-400 1/32 5/16 DR-400 (0.8) (8.0) Figure 54 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 11. HOOD INSTALLATION All of these appliances must have hoods installed prior to operating. On all clean face units, slide the hood into the slots on the lower edge of the radiant panel (Figure55 ). On louvered face units, slide the hood into the slots on the lower edge of the cabinet top (Figure 56). FINISHING REQUIREMENTS Wall Details Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (Figures 55 and 56). Combustible Finished Wall Materials This Area Must Remain Clear of Combustible Materials Top of Appliance 1" Min (25 mm) Spacer Clean Face Models Top of Door Frame Hood must be installed as shown. Radiant panel Combustible material may touch theappliance top. Combustible materials not allowed below this point onthe face of the appliance. Figure 55 Combustible Finished Wall Materials This Area Must Remain Clear of Combustible Materials Top of Appliance 1" Min (25 mm) Spacer Louver Face Models Top of Door Frame Combustible material may touch theappliance top. Hood must be installed as shown. Louvers Combustible materials not allowed below this point onthe face of the appliance. Figure 56 24 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. *All compressed flex vents can be expanded up to two times. Listed Secure Flex™Components Cat. No. Model No. Description These termination kits include firestop/spacer, gear clamps and flex adapter. 86L94 SF-HTR Horizontal Round Termination without Flex 77L82 SFKIT12R Flex Round Term. with 12 in. (305 mm) of *compressed Flex 77L83 SFKIT18R Flex Round Term. with 18 in. (457 mm) of *compressed Flex 77L84 SFKIT24R Flex Round Term. with 24 in. (610 mm) of *compressed Flex 77L85 SFKIT36R Flex Round Term. with 36 in. (914 mm) *compressed Flex 77L86 SFKIT48R Flex Round Term. with 48 in. (1219 mm) of *compressed Flex 87L01 SFHRK Snorkel Riser Kit with Flex Adapter, a section of Flex, and Gear Clamps 19M40 SF4.5HF Firestop/Spacer- Horizontal (3-1-1 spacing) 19M41 SF4.5BF Firestop/Spacer- Vertical (1-1-1 spacing) 12 (305) MANTEL 10 (254) MANTEL 8 (203) MANTEL 6 (152) MANTEL 4 (102) MANTEL 4 (102) 14 (356) 12 (305) 10 (254) 2 (51) MANTEL TOP OF APPLIANCE 6 (152) NOTE - Hood shown as positioned in louvered front model. The hood position in the flush faced front model is lower than shown. 8 (203) MANTEL CLEAR...

Ce manuel est également adapté pour les modèles :
Cheminées - DT-400CEP (973.7 kb)
Cheminées - DT-400CEN (973.7 kb)
Cheminées - DT-400CEP (973.7 kb)
Cheminées - DR-400CEN (973.7 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories