Log:
Évaluations - , GPA: ( )

Instructions Desa, Modèle (V)DVF36TCRP(E)

Fabricant : Desa
Taille : 2.04 mb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


To install, plug extension cord into one of the outlet receptacles on the outlet box. Plug receiver unit into extension cord and the ignition module into receiver unit (see Figure 37). 4. Replace louvered access panel by following reverse steps on page 18. 5. Activate handset battery by removing insulating tab on back (see Figure 38). Battery Cover Installation Continued Remote Control Unit Battery Cover 12 Volt Battery Sensor Tag Pull to Remove Insulation Tab Terminal Wires Battery Housing Figure 38 - Installing Battery in Hand- Held Remote Control Unit (SKYTECH) 9-Volt Battery GAS LINE HOOK-UP WARNING: Before you proceed, make sure your gas supply is OFF. WARNING: Gas line hookup should be done by your gas supplier or a qualified service person. An equipment shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 39. Route a 1/2" NPT black iron gas line towards the appliance coming in from the left. It is recommended to route the pipe between the stand of the firebox and the surround of the fireplace (see Figure 40, page 21). Figure 36 - Installing Battery in Hand- Held Remote Control Unit (HRC100) Shutoff Valve Optional Fan Kit Plug Outlet Box Key Extension Cord Receiver Extension OFF PILOT ON LO HI PILOT EA16AI7TPTH TP TH Gas Valve Figure 39 - Typical Exterior Wall Gas Shutoff Installation White Red To Thermopile Figure 37 - Installing Remote Receiver (SKYTECH Model) IMPORTANT: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig. (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.5 kPa). CAUTION: Do not kink flexible gas line. CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or propane), and should be applied lightly to ensure excess sealant does not enter the gas line. 1. Install a sediment trap between the incoming gas line and the gas control valve (see Figure 40). The sediment trap should extend down the center of the pipe. Refer to your local codes. 2. Prepare incoming gas line and check with local codes regarding the use of teflon tape. Complete your gas line installation by connecting incoming gas line with flexible gas line. Secure tightly with a wrench, but Do NOT Overtighten. WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier. Gas Supply Testing Note: This section is intended as a guide for qualified service technicians installing gas to the appliance. CAUTION: Do not connect appliance before pressure testing gas piping. Damage to the gas valve may result and an unsafe condition may be caused. The millivolt system with a manual HI/LO applies only to the DVF36TCR, DVF36TCRP, DVF36TCL and DVF36TCLP models. The gas control valve is accessible from the lower control compartment. Two pressure taps are provided on the gas control valve for a pressure gauge connection (see Figure 41, page 22). The electronic system applies to the DVF36TCRE, DVF36TCRPE, DVF36TCLE and DVF36TCLPE models (see Figure 42, page 22). Installation Continued Incoming 1/2" Gas Line Permitted by Local Codes 3" Min. Side Wall Of Appliance Sediment Trap (Not Supplied) Figure 40 - Sediment Trap Installation Continued Pilot Adjustment Cap Pilot Gas Line Do Not Kink To Pilot Burner ON/OFF Knob OFF PILOT ON LO HI PILOT EA16AI7TPTH TP TH OpenClose To Main Burner Flame Adjustment Knob Inlet Pressure Outlet Pressure Figure 41 - Millivolt Control Valve From Gas Supply Figure 43 - Opening Door Latches EAOLHILPIOT B C D A To Main Burner Flame Adjustment Knob A E Inlet Pressure Outlet Pressure C Figure 42 - Electronic Control Valve D Installing Log Set Before proceeding, make sure the gas control valve is in the OFF position. Logs have been shrink wrapped on a cardboard backing to prevent breakage during shipping. Cut around perimeter of each log and pull gently on shrink-wrap to expose log. Do not pull on log to release it from the shrink- wrap as this may damage logs. 1. Remove lower louver access pane...

Ce manuel est également adapté pour les modèles :
Cheminées - (V)DVF36TCLP(E) (2.04 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories