Instructions Enviro, Modèle DV42DX

Fabricant : Enviro
Taille : 1.84 mb
Nom Fichier : be6864d4-7ff7-43b5-886d-e54f17e811ee.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 15. Light the appliance and ensure proper operation. OTHER APPROVED VENT PARTS: Table 3: Approved Vent Manufacturers Manufacturer Trade Name Nominal Sizes American Metal Products AmeriVent Direct 4” - 6 5/8” Security Chimneys International LTD Secure Vent 4” - 6 5/8” Selkirk Metalbestos Direct-Temp 4” - 6 5/8” Simpson Dura-Vent Direct Vent GS 4” - 6 5/8” The Retreat fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements. WARNING: Do not mix parts from different vent manufacturers’s systems. EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Initial Installation QUALIFIED INSTALLERS ONLY 1 Initial Installation QUALIFIED INSTALLERS ONLY Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct- Temp Secure Vent Ameri Vent Direct Description 908 4DT-6 SV4L6 6” pipe length 4D7 7” pipe length 907 4DT-9 9” pipe length 906 4DT-12 SV4L12 4D12 12” pipe length 904 4DT-24 SV4L24 4D2 24” pipe length 903 4DT-36 SV4L36 4D3 36” pipe length 902 4DT-48 SV4L48 4D4 48” pipe length 945 4DT-EL45 SV4EBR45 4D45B 45° elbow, black 990 4DT-EL90 SV4EBR90 4D90B 90° elbow, black 950 4DT-VS SV4VS Vinyl siding standoff/sheild 942 4DT-WT SV4RSN 4DWT Wall thimble 953 4DT-SC SV4FC 4DSC Storm collar 963 4DT-FS SV4BF 4DFSP Fire stop 988 4DT-WS/B SV4BM 4DWS Wall strap/support/band 970 4DT-HKA SV0SHK 4DHTK1 Horizontal termination kit (SD: Basic Kit, SEL: Kit A, SC: Standard Kit) 911 11” to 14 5/8” pipe, adjustable 4DT-AJ 4D12A 4” to 10” pipe , adjustable SV4LA12 11.2” to 12” pipe , adjustable 943 4DT-AF6 4DF Flashing, 0/12 to 6/12 roof pitch 943S 4DT-AF12 4DF12 Flashing, 7/12 to 12/12 roof pitch SV4FA Flashing, 1/12 to 7/12 roof pitch SV4FB Flashing, 8/12 to 12/12 roof pitch 943F SV4F Flat flashing 980 4DT-VC SV4CGV 4DVC Vertical termination 991 4DT-HVC High wind vertical termination 984 4DT-HC SV4CHC 4DHC Horizontal square termination 985 4DT-HHC High wind horizontal termination 978 4DT-VKC SV0FAK 4DVTK Vertical termination kit 971 4DT-HKB SV0SHK2 4DHTK2 Horizontal termination kit (SD: Kit A, SEL: Kit B, SC: Kit) 1 Initial Installation QUALIFIED INSTALLERS ONLY VENTING: This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, and MDV SELKIRK METALBESTOS. A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11.2” (38 mm) on the sides and bottom. When combustible materials are directly above a 90° elbow, 5” (127 mm) of clearance are necessary (see Figure 20). Table 5. Vent Pipe Minimum Clearances. Vertical Pipe to the Side Walls Horizontal Pipe to the Sides & Bottom Above an Elbow Above the Unit Above an Elbow Not Above the Unit Above Horizontal Vent Pipe Wall Frame 8” (203mm) or less Hard Pipe 1” (25.4 mm) 11.2” (38.1 mm) 4” (102 mm) 3” (76.2 mm) 2” (51 mm) 10”x10” (25x25cm) Flex Pipe 1” (25.4 mm) 11.2” (38.1 mm) 8” (203 mm) 4 3/8” (111 mm) 4 3/8” (111 mm) 10”x10” (25x25cm) A 10” (254 mm) x 10” (254 mm) frame (see Figure 24) will assure the proper support and spacing for the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used for passing through walls and ceilings. All sealing and vapour barriers must comply with local building codes. When planning an installation, it is necessary to select the proper length of vent pipe for the particular requirements. The configuration of the venting pipes depends on the locations of walls, ceilings and studs. However, the pipes cannot be of arbitrary length and arrangement. Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace, certain guidelines have been set in INITIAL INSTALLATION - VENT CONFIGURATIONS AND RESTRICTOR SETTINGS. Venting terminals can not be recessed into a wall or siding. WARNING: This gas appliance must not be connected to a chimney flue serving a separate solid-burning appli...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories