Fabricant : Napoleon Grills
Taille : 2.87 mb
Nom Fichier : ddaeccdd-346a-420b-b360-261a11af63b1.pdf
|
Facilité d'utilisation
Keep burner and control compartment clean. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles burning off. operation. Verify proper operation after servicing. This heater should be inspected and serviced before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed. 2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year. 3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly. 4. Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and promptly ignites the main burner. 6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your NAPOLEON® dealer / distributor. Cleaning Stainless Steel: Do not use abrasive cleaners to clean any painted, porcelain or stainless steel parts. To clean stainless surfaces, use a stainless steel cleaner or a nonabrasive cleaner. Always wipe in the direction of the grain. VENTURI ADJUSTMENT Air shutter adjustment must only be done by a qualified gas installer! Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established. Opening the air shutter will also reduce exhaust odours. See Trouble Shooting Guide. AIR SHUTTER OPENINGS NG 3/16” LP 1/4” REPLACEMENTS REPLACEMENTS Contact your dealer for questions concerning prices and When ordering replacement parts always give the following policies on replacement parts. Normally all parts can be information: ordered through your NAPOLEON® dealer or distributor. 1. MODEL & SERIAL NUMBER OF FIREPLACE 2. INSTALLATION DATE OF FIREPLACE 3. PART NUMBER FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF 4. DESCRIPTION OF PART THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR 5. FINISH THE CLAIM. * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR NAPOLEON® DEALER. REPLACEMENT PARTS # PART NO. DESCRIPTION 15 W010-1066 PAN BURNER 1 W357-0001 PIEZO IGNITER 16 W455-0078 #31 NATURAL GAS BURNER ORIFICE 2 W680-0004 THERMOPILE 16 W455-0042 #49 PROPANE GAS BURNER ORIFICE 3 **W680-0005 THERMOCOUPLE 17 W335-0033 HOOD 4 W010-0800 NATURAL GAS PILOT ASSEMBLY 18 W565-0062 CURTAIN MESH 4 W010-0801 PROPANE GAS PILOT ASSEMBLY 19 W555-0040 CURTAIN ROD 5 W455-0069 NATURAL GAS PILOT INJECTOR 20* W080-0614 CURTAIN ROD BRACKET 5 W455-0067 PROPANE GAS PILOT INJECTOR 21 W500-0209 CURTAIN SUPPORT PLATE 6 W725-0028 NATURAL GAS VALVE 22 W630-0010 BLACK TASSELS 6 W725-0029 PROPANE GAS VALVE 23 W200-0135 FIREBOX COVER 7* W385-0334 NAPOLEON® LOGO 24 N325-0036 COVER HANDLE 8 GL-639OD LOG SET 25* W660-0005 SWITCH 9 10 11 W135-0183OD W135-0184OD W135-0185OD BACK LOG (#1) LEFT MIDDLE LOG (#2) RIGHT MIDDLE LOG (#3) 26* 27* 28 W750-0109 W750-0110 GVFLSS 3/16” FLAG WIRE ASSEMBLY 1/4” FLAG WIRE ASSEMBLY LOUVRE KIT - STAINLESS STEEL 12 W135-0186OD LEFT CROSSOVER LOG (#4) 13 W135-0187OD MIDDLE CROSSOVER LOG (#5) 14 W135-0188OD RIGHT CROSSOVER LOG (#6) ** WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. W415-0369 / E / 02.16.07 TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot flame is not large enough -turn up pilot flame. out; pilot stays on. or not engulfing the thermo-- replace pilot assembly. pile Thermopile shorting - clean thermopile connection to the valve. Reconnect. - replace thermopile / valve. Remote wall switch wire is too -shorten wire to correct length or wire gauge. long; too much resistance in the system. Faulty thermostat or switch. -replace. Pilot goes out when System is not correctly -purge the gas line. the gas knob is re-purged. leased. Out of propane gas. -fill the tank. The gas valve has Pilot flame is not large -turn up the pilot flame. an interlock device enough which will not al low the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool. Pilot burning; no gas to main burne...
Ce manuel est également adapté pour les modèles :Cheminées - GSS36P (2.87 mb)