Instructions Hearth and Home Technologies, Modèle 8000CF-OAK-IPI

Fabricant : Hearth and Home Technologies
Taille : 3.46 mb
Nom Fichier : ae4d7af4-0211-4276-8c72-dacc2ef317e4.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


D. Mantel and Wall Projections Combustible Mantel Legs or Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc). Combustible Mantels Note: All measurements in inches. 18 14-1/4 10-1/2 6-3/4 3 7-3/4 8-7/8 10 11-1/8 12-1/4 MEASUREMENTS FROM TOP EDGE OF HOOD Figure 5.4 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) 1 in. MIN. 3 in. MIN. 3 ft. MAX. TOP VIEW Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 6 66 Termination Locations A. Vent Termination Minimum Clearances WARNING Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fire. HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X/ 12 LOWEST DISCHARGE OPENING 2 FT. MIN. 20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12.................................................1.25* Over 7/12 to 8/12.................................................1.5* Over 8/12 to 9/12.................................................2.0* Over 9/12 to 10/12...............................................2.5 Over 10/12 to 11/12.............................................3.25 Over 11/12 to 12/12.............................................4.0 Over 12/12 to 14/12.............................................5.0 Over 14/12 to 16/12.............................................6.0 Over 16/12 to 18/12.............................................7.0 Over 18/12 to 20/12.............................................7.5 Over 20/12 to 21/12.............................................8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Figure 6.3 Leveled Termination Caps DIRECT VENT GAS, WOOD OR FUEL OIL TERMINATION A GAS TERMINATION B C Gas Termination Wood & Fuel Oil Termination Comments A 6 in. 20 in. Horizontal distance between terminations B 20 in. 24 in. Distance to perpendicular wall C 18 in. 18 in. Vertical distance between terminations Minimum Dimensions DIRECT VENT GAS, WOOD OR FUEL OIL TERMINATION 20 IN. (508 MM) (MINIMUM) TO PERPENDICULAR WALL (GAS ONLY) WOOD OR GAS TERMINATION 20 IN. MIN. * (508 MM) * IF USING DECORATIVE CAP COVER(S), THIS DISTANCE MAY NEED TO BE INCREASED. REFER TO THE INSTALLATION INSTRUCTIONS SUPPLIED WITH THE DECORATIVE CAP COVER. Figure 6.2 Staggered Termination Caps Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 22 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08 O N P R Q V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for Termination A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 inches.................clearances to window or door that may be opened, or to permanently closed window. (Glass) C = 18 inches.................vertical clearance to unventilated soffi t or to ventilated soffi t located above the terminal 30 inches .................for vinyl clad soffi ts and below electrical service D = 9 inches..................clearance to outside corner E = 6 inches...................clearance to inside corner F = 3 ft. (Canada) ..........not to be installed above a gas meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator G = 3 ft. ..........................clearance to gas service regulator vent outlet H = 9 inches (U.S.A.) 12 inches (Canada) clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance i = 3 ft. (U.S.A.) 6 ft. (Canada) ...........clearance to a mechanical (powered) air supply inlet CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. ** a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. *** only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the fl oor, or meets Note 2. Note 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page) Note 2: Termination in a covered alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specifi ed for vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 fee...

Ce manuel est également adapté pour les modèles :
Cheminées - 8000CFLP-OAKIPI (3.46 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories