Log:
Téléchargements : 5   Taille : 5 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

ELECTRICAL WIRING DIAGRAM Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes. If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing location must be followed. 5 MAINTENANCE OF MOTORS The motors used on the fan and flame generator assembly are prelubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacu

Téléchargements : 11   Taille : 5 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

Parts having to be removed for servicing must be replaced prior to operating this electric fireplace again. 8. Do not use outdoors. 9. This heater is not intended for use in bathrooms, laundry areas or similar indoor locations. Never use this appliance near a bathtub or other water container. 10. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over. 11. To disconnect this appliance, tur

Téléchargements : 5   Taille : 5 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

Connect to properly grounded outlets only. 13. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock, fire or damage to the appliance. 14. To prevent fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, such as a bed, where openings may become blocked. 15. This appliance has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. T

Téléchargements : 3   Taille : 5 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

1. Make sure the unit is unplugged from the power source. 2. Plug the fireplace into a 10AMP/220V outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1900 watts. To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A). A. MAIN ON/OFF SWITCH The on/off switch supplies power to all fireplace functions (heater/flame). B. HEATER THERMOSTAT CONTROL To adjust the temperature to your needs, turn the thermostat control complet

Téléchargements : 65   Taille : 5 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE INSTALLER: DO NOT DISCARD THIS MANUAL-LEAVE FOR HOME OWNER PC(220)-VCL100-01-0709 2 PLEASE READ THE INSTALLATION & OPERATION INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty. I

Téléchargements : 7   Taille : 7 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE PC(220)-FE23A610-0709 Installation Instructions and Owner’s Manual INSTALLER: DO NOT DISCARD THIS MANUAL-LEAVE FOR HOME OWNER SFE23RE SHOWN WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICIN

Téléchargements : 6   Taille : 7 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

For convenience, if one of the bulbs burns out, it may be a good idea to replace all of the light bulbs. 1. Turn off power to the unit by unplugging the power cord. 2. Let fireplace cool if it has been operating. 3. Remove the two screws on the top corner of screen. Pull the screen upward slightly, and then pull out. 4. Remove the four screws that secure the log set/ember bed in position. 5. Remove log set / ember bed and grate assembly. 6. Examine the bulb(s) to determine which bulbs need to be

Téléchargements : 2   Taille : 2 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

(See FIG 4). Installing logs for SFE23RE: 4.Insert the pin on log 6 to the recessed hole on log 4, and place log 6 as figure shows. (See FIG 9). Installing logs for SFE33RE: FIG 1 - Logs for SFE23RE 1.Insert the two pins on log 1 to the two recessed holes at the middle of grate. (See FIG 2). 2.Insert the pin on one end of log 2 to the recessed hole on log 1, with the other end of log 2 placed on the ember bed (where marked). (See FIG 3). FIG 5 - Logs for SFE33RE 1.Place log 1, log 2 and log 3 in

Téléchargements : 0   Taille : 2 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

(2) Flame brightness Press “SET”button, when the lamp symbol flashes, press button to decrease the flame brightness and button to increase the flame brightness. 7. For Flame Effect only: Select MANUAL mode, then set the Heating level to no heating level or select AUTO mode and then set temperature to lowest setting. 8. Manual ON/OFF button If you can’t find your Remote Control or the Remote Control is damaged, you can use manual ON/OFF button to manual turn on/turn off your heater. 2. The Clock

Téléchargements : 0   Taille : 2 mb   Fabricant : Procom  
Catégorie : Cheminées
@name

4 Wire Gauge: Power Cord 14AWG Heater Element 16AWG Other Wire 18AWG Model: SFE23RE, SFE33RE Voltage: 120 VAC, 60 Hz Total Amps: 11.5 Amps Total Watts: 1380 Watts Heater Rating: 1200 Watts Operating Instructions Before programming your transmitter you must first insert three triple “AAA”batteries. Make sure the main power on/off swith is in “ON” position. 1. The Mode setting: Press the “SET”button, then the “AUTO”light will flash. Press the “SET”button again, and then the “MANUAL”light will also