To reset press and hold CANCEL for 3 seconds, or re-energize the brewer. (Possible causes of the problem are: no incoming water; slow flow of incoming water, sensor not reading, etc.). E. Keyswitch Locked: If a key switch is depressed for 10 seconds this error message will occur. Lights will flash alternately and the brewer will turn off all valves and elements. Press and hold the CANCEL key for 3 seconds to reset the brewer (or re-energize the brewer). If the problem re-occurs this indicates a defective switch on the key pad. F. “Valve Fault”- Faulty Valve Detection: When an electric or switching problem is detected with either the inlet or brew valve the brewer turns off all elements and valves and displays “valve fault…”. All of the lights will be turned on. Before re-setting the brewer the valves must be checked to determine the problem. The brewer must be re-energized to re-set, (pressing CANCEL for 3 seconds will not reset a valve fault). 10 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS CAUTION: Burn Hazard PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns. Bristle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove dispenser. 3. Remove and empty brew chamber. 4. Remove the spray disk from the brew head: Press up on the spray disk ears, then turn the disk to the left to unlatch. Remove the gasket from inside the brew head. 5. Wipe inside of brew head and area around the brew head with a soft clean cloth or sponge moistened with clean water. 6. Wash the spray disk in a sink using warm water and a mild detergent. A bristle brush may be used to clear clogged spray holes. Rinse the spray disk with clean water and allow to air dry. 7. Wash the brew chamber in a sink using warm water and a mild detergent. A bristle brush may be used to clean the inside. Rinse with clean water and allow to air dry. 8. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 9. Reinstall the brew chamber. 10. Dispensers may be washed in a dishwasher, or in a sink with warm water and mild detergent. Rinse thoroughly and dry with a soft cloth. Procedure is complete CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. Do not pour or splash water into or over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or dispensers 11 FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller. NOTE: The solenoid has an internal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of the strainer and pull straight out. Wash any debris from the strainer. Note orientation - DO NOT reverse strainer. Reassemble and reinstall. Turn water supply back on. 2. Water is diverted to the spout assembly (51) thru the bypass hose (52. 3. Water enters the tank (2) thru the fill tube (16). Water is heated in the tank by the heating element (15). 4. The tank lid (9) is sealed around the edge with a gasket (6), and is secured by 3 clips (10). 5. Heated water is dispensed to the brew head through the brew tube (14), brew solenoid (18), and spout of the brew fitting (19). The brew solenoid is energized during the brew cycle by the controller. NOTE: The flow rate of the brew solenoid is factory set. DO NOT adjust. 6. Hot water is sprayed over the coffee grounds by the spray disc (24), which is sealed to the brew head by a gasket (23). 7. The tank is vented through the vent elbow fitting (40) and vent tubes (11 & 13). 8. Water for the hot water faucet (1) is supplied from the tank through the faucet supply tube (12). SERVICING INSTRUCTIONS — PLUMBING 12 SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2030 6 GASKET, TANK LID 83499 2030 9 TANK LID 83504 2030 10 RETAINING CLIP, TANK LID 83506 2030 11 HOSE, VENT (SILICONE 4.5” LONG) 86014 2030 12 HOSE, FAUCET SUPPLY (SILICONE, 10” LONG) 83538 2030 13 TUBE, VENT (METAL, 2.3” LONG) 83384 2030 14 TUBE, VENTED ASSEMBLY 16 TUBE, FILL (SILICONE, 35“ LONG) 83540 2030 18 SOLENOID, BREW (DUMP) 83388 2030 19 ELBOW, BREW 83152 2030 22 23 GASKET, SPRAY HEAD 82215 2030 24 SPRAY DISK 82727 2030 32 SOLENOID, FILL 83612 2030 40 INSERT, BREW SPOUT 83571 2030 51 SPOUT ASSY 82941 2030 52 TUBE, BYPASS (SILICONE 30“ LONG) 83978 2030 FAUCET, HOT WATER 8783-1 2030 86013 2030 ELBOW, VENT 8043-11 2030 SERVICING INSTRUCTIONS - ELECTRICAL FUNCTION 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. Automatic fill ...