The IMPRESSA recognizes when you should run a decalcifying cycle. The machine will still make coffee, hot water and steam. However, we recommend that you should decalcify the machine (see Chapter 16) within the next few days. SELECT PRODUCT / DE-SCALE MACHINE After a while the display will change. You should run the decalcifying cycle now (see Chapter 16). SELECT PRODUCT / DE-SCALE NOW 15.10 Emptying the system Requirements: The IMPRESSA has been switched off with the ON / OFF key (11), but the power switch (27) is still turned on. This is necessary to protect the machine against damage occurring during transport as a result of frost. Place a receptacle under the pivoting steam spout (23). Press one of the Steam keys until the following message is displayed: SYSTEM EMPTYING When the process has been completed, the IMPRESSA switches itself off. The display will read “FILL SYSTEM / PRESS STEAM” next time you switch the machine on. For more information, please refer to Chapter 3 “First use”. 23 E 15.11 General cleaning instructions Never use sharp objects or caustic chemicals for cleaning. Clean the case using a soft, damp cloth. Clean the pivoting steam spout (23) after each use. After heating milk, draw off some hot water to clean the inside of the pivoting steam spout (23). Remove the Professional-Cappuccino Frother to clean it thoroughly. The water tank should be rinsed out and filled with fresh water daily. Visible calcification in the water tank can be removed using a commercial decalcifying agent. To do so, remove the water tank from the machine. If you are using a CLARIS plus filter cartridge, remove it from the tank first. 16. Cleaning The IMPRESSA features an integrated cleaning program. The process takes approx.15 minutes. Please contact your authorized dealer for JURA cleaning tablets that are suitable specifically for the cleaning program of your IMPRESSA. Please note that the use of unsuitable cleaning agents may cause damage to your machine and could leave unfavourable residues in the water. Once started, the cleaning process must not be interrupted. SELECT PRODUCT CLEAN MACHINE Press Rinse until the following message appears: EMPTY TRAY / EMPTY GROUNDS Empty out the drip tray (1) and the coffee grounds bin (Fig. 15). TRAY MISSING Place the empty, clean drip tray (1) and the coffee grounds bin back into the IMPRESSA. PRESS RINSE Place a sufficiently large receptacle (ca. 0.5 litres) under the coffee spout (18). Press Rinse . MACHINE CLEANING You will hear an acoustic signal. ADD TABLET / PRESS RINSE Open the lid of the filler funnel for pre-ground coffee (17). Drop a JURA cleaning tablet inside (Fig. 12) and close the lid. Press Rinse . MACHINE CLEANING You will hear an acoustic signal. EMPTY TRAY / EMPTY GROUNDS Empty out the drip tray (1) and the coffee grounds bin (Fig. 15). TRAY MISSING Place the empty, clean drip tray (1) and the coffee grounds bin back into the IMPRESSA. SELECT PRODUCT When the cleaning program has finished, take out the removable coffee powder tank and briefly rinse it under running water. You can also trigger a cleaning cycle manually at any point in time (see Chapter 13.3). 17. Decalcifying The IMPRESSA features an integrated decalcifying program. The process takes approx.50 minutes. Lime scale builds up in the IMPRESSA as a result of normal use. The degree of calcification depends on the hardness of the water you use. The IMPRESSA recognizes when you should run a decalcifying cycle. The machine will still make coffee and hot water/steam. However, we recommend that you should decalcify the machine within a few days after the message was displayed. Please contact your authorized dealer for JURA decalcifying tablets that are suitable specifically for the decalcifying program of your IMPRESSA. Please note that the use of unsuitable decalcifying agents may cause damage to your machine and could leave unfavourable residues in the water. Remove any splashes or drops of the decalcifying agent from sensitive surfaces, in particular surfaces made of natural stone or wood, or take appropriate preventive measures. Once started, the decalcifying program must not be interrupted. Always wait until the decalcifying agent has been used up and the tank is empty. Never fill in additional decalcifying agent. SELECT PRODUCT DE-SCALE MACHINE Press Rinse until the following message appears: EMPTY TRAY / EMPTY GROUNDS Empty out the drip tray (1) and the coffee grounds bin (Fig. 15). TRAY MISSING Place the empty, clean drip tray (1) and the coffee grounds bin back into the IMPRESSA. AGENT IN TANK / PRESS STEAM Take out the water tank (14). Empty out any remaining water. Completely dissolve the content of one blister (3 tablets) in a receptacle containing 0.6 litres of water, and pour the mixture into the water tank. Place the water tank back into the machine. Remove the 2-stage frothing jet (24) or Professional-Cappuccino Frother from the machine (if attached). Pl...
Ce manuel est également adapté pour les modèles :Cafetières - IMPRESSA XS90 (474.94 kb)