Log:
Évaluations - 2, GPA: 3.5 ( )

Instructions Fujitsu, Modèle PRIMERGY BX400 S1

Fabricant : Fujitsu
Taille : 2.85 mb
Nom Fichier : bx400s1-om-en.pdf
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


Figure 12: ServerView Local Service Display for Blade (floorstand version) At the BX400 S1 system unit floorstand version, the ServerView Local Service Display for Blade is placed on top of the system unit. 60 Operating Manual BX400 S1 Installation and operation 12 34 56 7 Figure 13: Control and display elements on the front of the ServerView Local Service Display for Blade 1 CSS indicator 5 power-on indicator 2 Global Error indicator 6 ID indicator 3 ID button 7 Navigation buttons for the LocalView menu system 4 On/Off button BX400 S1 Operating Manual Installation and operation 5.1.1.1 Control elements On/Off button When the system is switched off, it can be switched on again by pressing the On/Off button. When the system is operating, pressing the On/Off button will switch off the system. V CAUTION! Risk of loss of data! I The On/Off button does not disconnect the server from the mains voltage. To disconnect from the mains completely, remove the power plug(s). ID ID button Lights up (blue) on the front and on the rear of the system unit when the ID button is pressed. The two ID indicators are synchronized. Navigation buttons for the LocalView menu system With the buttons , , and you select a function. Pressing the button executes the selected function. 5.1.1.2 LEDs on the control panel Power indicator (two-color) Lights up green when the system unit is switched on. Lights up orange when the system unit is switched OFF, but mains voltage is present (standby mode). 62 Operating Manual BX400 S1 Installation and operation ! Global Error indicator (orange) – Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. – Flashes orange if an error was detected that requires service intervention. – Does not light up if there is no critical event. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. You can find more details on the indicated errors in the System Event Log (SEL), in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local Service Display, in the ServerView Operations Manager or via the iRMC S2/S3's Web interface. CSS CSS indicator (yellow) – Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept. – Flashes yellow if an error was detected that you can fix yourself with the CSS concept. – Does not light up when the system is OK. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. For more information on the CSS concept, see "Customer Self Service (CSS)" on page 13. ID ID indicator (blue): Glows blue when the system was selected by pressing the ID button. Pressing the button again deactivates the LED. The ID indicator can also be activated via the management blade web interface and via the ServerView Operations Manager and its status reported to the ServerView Operations Manager and the iRMC S2/S3. BX400 S1 Operating Manual Installation and operation 5.1.1.3 System ID card Rack model Floorstand model Figure 14: System ID card location The ID card contains various system information, such as the product name,serial number, order number (in the Japanese market, only the product name, the serial number). 64 Operating Manual BX400 S1 Installation and operation 5.1.2 Back of system 5.1.2.1 Control and display elements on the management blade 12 3 45 6 78 91011 Figure 15: Control and display elements on the management blade 1 Status indicator (yellow) Lights up when the management blade is active (master) Is not lit when the management blade is not active (slave) Blinks when the management blade is defective. 2 LAN link indicators (service LAN port) Lights up green if a LAN connection exists. Does not light up if no LAN connection exists. 3 LAN activity indicators (service LAN port) Flashes yellow for a LAN transfer is in progress. Does not light up if no LAN transfer. BX400 S1 Operating Manual Installation and operation 4 Global Error indicator (orange) – Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. – Flashes orange if an error was detected that requires service intervention. – Does not light up if there is no critical event. If the event is still acute after a power cycle, the indicator is activated after the restart. The indicator also lights up in standby mode. You can find more details on the indicated errors in the System Event Log (SEL), in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local Service Display, in the ServerView Operations Manager or via the iRMC S2/S3's Web interface. 5 CSS indicator (yellow) – Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with ...

Ce manuel est également adapté pour les modèles :
Ordinateurs - PRIMERGY BX400 S1 (2.85 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories