Log:
Évaluations - 2, GPA: 3.5 ( )

Instructions NewAir, Modèle ACP-1300E

Fabricant : NewAir
Taille : 349.67 kb
Nom Fichier : afc800e1-ac79-4afd-bba0-66ce2bbd1c96.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


3 (3) Maintenance......................................... ................................... 4 2. Parts List (1) ACP-1300E Unit and Accessories............................................... 5 (2) Control Panel ........................................................................... 6 (3) Remote Control......................................................................... 7 (1) Operating the ACP-1300E for the First Time; Operating Modes; and Thermostat.........................................................................8 (2) Setting the Timer....................................................................... 9 (3) Adjusting the Airflow...................................................................9 (4) Installing the Battery for the Remote Control...............................10 (5) Emptying the Auxiliary Water Tank.........................................11-12 (6) Setting up the Exhaust Hose.................................................13-14 4. .......................................................................15 5. ..........................................................................16 6. ................................................................ 17 3.Operating Instructions Troubleshooting Tips Electrical Diagram Electrical Specifications Contents 1 Connect the ACP-1300E's plug into an appropriate power outlet. Do not turn off the power supply by pulling the power cord; use the On/Off power button. Make sure the air conditioner's ground wire is connected. If you notice smoke or an odd odor coming from the ACP-1300E, turn the unit off and disconnect the power plug. To avoid injury, keep fingers and foreign objects out of the unit. 1. Safety Instructions Warning If problems persist or if the unit malfunctions, please contact your NewAir dealer or a professional repair center. Before operating the ACP-1300E, make sure your hands are clean and dry. 2 Be careful not to damage the power cord, and do not operate the ACP-1300E if the cord appears to be damaged. Do not use a power strip or an extension cord. Precautions 1. Safety Instructions 3 Leave the ACP-1300E in an upright position for at least two hours before operating. The unit must be installed in accordance with national and local wiring regulations. The ACP-1300E's supply cord requires a Y-type attachment. If the supply cord is damaged, it must be replaced by the manufacturer, an authorized service agent, or a qualified repair professional in order to avoid further damage, to prevent voiding the warranty, and to avoid bodily injury. Never operate the ACP-1300E in an area where flammable gasses or chemicals are present. To prevent electromagnetic interference, place the unit at least three feet away from radios or televisions. When connecting or disconnecting the power cord, hold the plug itself - never pull the power cord. When not using the unit for an extended period of time, disconnect the power cord and drain any water from the auxiliary water tank. When cleaning the ACP-1300E, do not spray liquid directly onto the unit. Moreover, do not use harsh chemicals or cleansers to clean the unit. Instead, apply water or a mild cleanser to a soft cloth and wipe the ACP-1300E clean. The ACP-1300E is not intended to support heavy objects, be used as a step-stool, or be shaken or bumped into. Keep this in mind when deciding where to place the unit. If you choose to use the continuous drain function on the ACP-1300E, make sure the condensate can drain off into an appropriate receptacle. To ensure adequate air circulation, place the air conditioner at least four inches away from walls and furnishings. Be aware of draperies or other items which may interfere with the intake vents and cause restricted airflow. Place the ACP-1300E on a level, flat surface. Do not operate the unit on an angle of more than 4 inches. Maintenance 1. Safety Instructions 4 Please Note: When cleaning the air filter, use only warm water or a mild detergent. Once the filter has been cleaned, allow it to completely dry in a cool place. Also remember that the external case should only be cleaned with a soft, moist cloth. To avoid electrical shock, be sure to disconnect the power cord before cleaning the unit. Avoid using chemicals such as benzene, alcohol, gas, or turpentine when cleaning the unit. It is recommended that the air filter be replaced every two months (more frequently if the filter is visibly soiled). Built-up dust and debris on the filter will decrease airflow and impact the air conditioner's cooling efficiency. When removing the filter from the ACP-1300E, following these steps: 1.Gently lift up the air filter cover. 2.Grasp the air filter and separate it from the cover. 2. Parts List Parts and Accessories 1.Control Panel 2.Air Outlet 3.Remote Sensor 4.Handle 5.Exterior Air Inlet 6.Caster 7.Filter 8. 9.Power Cord 11.Exterior Air Inlet 12.Cover Board 13.Exhaust Joint 14.Exhaust Joint 15.Exhaust Joint 16.Exhaust Joint 4 18.Water Tank Interior ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories