EdgeStar Portable Air Conditioner 12 Fan Only mode is used to circulate the air in your room. No temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the Power button. 3) Press the Mode button until the LED indicator next to “Fan Only” lights up. 4) Press the Speed button to select the fan speed. You can choose between High, Medium and Low. The LED indicator next to the speed will light up. The Speed button is used to change the fan speed while in Cooling and Fan Only modes. Press the Speed button to select the fan speed. The LED indicator light next to the High, Medium or Low will light up. The timer can be used to either turn the unit on or off after a number of elapsed hours. The timer is adjustable between 1-12 hours in one hour increments. How to set the unit to automatically turn on: 1) Press the Timer button while the unit is powered off. The Timer indicator LED will light up 2) Use the Up and Down buttons to set the time (displayed in hours). After the selected time passes, the unit will automatically turn on. How to set the unit to automatically turn off: 1) Press the Timer button while the unit is powered on. The Timer indicator LED will light up 2) Use the Up and Down buttons to set the time (displayed in hours). The unit will automatically turn off after the selected time elapses. The LCD Display will show the ambient temperature by default. Pressing the Up and Down buttons will show the set temperature for 15 seconds, and then revert to the room temperature. You can switch between Fahrenheit and Celsius by pressing both the Up and Down Buttons simultaneously. The displayed range of the ambient temperature is from 0. to 99.. Temperatures above 99. will be displayed as “Hi”, and temperatures below 0. will be displayed as “Lo”. If you enabled the Timer, the LCD Display will show the hour(s) set. In high humidity situations, the internal water reservoir may fill. The unit will automatically shut off and the water light will turn on. Once the water is manually drained, the unit will operate normally. Fan Only Mode Speed Timer LCD Display Water Light NOTE: Fan Only mode does not require that the exhaust hose be attached. NOTE: To cancel the timer, press the Timer button or Power button. 13 Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. Installing the batteries 1) Remove the cover on the back of the remote control. 2) Insert the batteries with the (+) and (-) ends pointing in the correct direction. 3) Slide the cover back on. Mode Button Up and Down Buttons Power Button Speed Button Timer Button CAUTION: Use only AAA batteries. Remove the batteries if the remote control will not be used for one month or longer. Do not attempt to recharge batteries not designed to be recharged. All batteries should be replaced at the same time. Do not mix old and new batteries. Do not dispose of batteries in a fire as they may explode. Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify, heat and fan modes. Speed Sets the fan speed between high, medium, or low. Timer . Used to enable the timer. . (Up) Increases the set temperature or the time when the Timer button is enabled. . (Down) Decreases the set temperature or time when the Timer button is enabled. NOTES: Be careful not drop the remote control. Do not place the remote control in a location exposed to direct sunlight. EdgeStar Portable Air Conditioner 14 Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner: . Do not cover the air outlet (exhaust) while in use. . Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake. . Minimize the length of the exhaust hose. . Make sure the exhaust hose is as straight as possible and avoid kinks or bends. . Keep curtains, blinds or drapes closed during the sunniest part of the day. . Use the timer to operate the unit before it is needed. For example, set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive. You may want to operate the unit all day if you live in a warmer climate. . Minimize the heat sources (direct sunlight, computers, servers, people, etc.) in the room. . Close all windows and doors. . Use the unit in a contained room. For example, a room with four walls and a ceiling, instead of a partitioned studio, or warehouse. . Make sure the unit is on a level surface. . Minimize the amount of humidity in the room. For example, run the unit as a dehumidifier. . To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on after shutting it off. . Inspect and keep the pre-filters clean by cleaning regularly. . Inspect and replace the activated carbon f...

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories