|
Facilité d'utilisation
Verify that all parts ordered were received as specified. See “Inventory” on page 6. Caution: Do not tip or place the unit on its side. Filing a claim If damage is identified on receipt of the cooling unit, note the damage on the bill of lading and file a damage claim with the shipping company. Contact APC for information on filing a claim with the shipping company. The shipping claim must be filed at the receiving end of the delivery. Caution: If damage is found, do not operate the unit. Keep all packaging for inspection by the shipper and contact APC customer support. See the back cover of this manual for contact information. InRoom SC 60 Hz User Manual Tools Required Phillips head screwdriver Inventory The cooling unit includes the remote control storage bracket, hardware, batteries, the remote control, and the exhaust kit. See “Remote Control” on page 17 for more information. See “Exhaust kit” on page 10 for contents. ON/OFF MODE SLEEP FAN TEMP TIME InRoomSC na3417aMODE TIMER FANSEND SLEEPDR Y Hr . Min ON/OFF + °F - °F Item Description Item Description 1 Cooling unit 4 Exhaust hose 2 Ceiling adapter 5 Exhaust cap 3 Phillips head screw ST 4.2 x 9.5 (2) 6 Remote control InRoom SC 60 Hz User Manual Component Identification ACPSC2000 and ACPSC3500 ON/OFF MODE SLEEP FAN TEMP TIME InRoom SC M O D ETIMER F A NS E ND S L EE PD R YHr .MinON / O F F + °F - °F ON/OFF MODE SLEEP FAN TEMP TIME InRoom SC na3354a Item Description 1 Control panel 2 Vertical air louver 3 Remote control / storage 4 Air filter / upper air intake (evaporator) 5 Air outlet (heat exchanger) 6 Power cord 7 Lower air intake (condenser) 8 Water outlet drain 9 Caster : Lower air intake (condenser) ; Handle InRoom SC 60 Hz User Manual Power plug Electrical Hazard: This equipment requires an LCDI plug. Use only the power cord supplied with the equipment. TESTPOWERRESETna3371a 1243 IN THE EVENT THIS DEVICE TRIPS, THE CAUSE OF THE MALFUNCTION IS TO BE CORRECTED BEFORE FURTHER USE OF THE DEVICE. SEE OWNERS MANUAL FOR ADDITIONAL INFORMATION. TESTING: 1. PRESS TEST BUTTON. LINE SHOULD TRIP. 2. PRESS RESET BUTTON FOR USE. DO NOT USE IF ABOVE TEST FAILS. Item Description 1 15 amp plug 2 Green (Power ON) LED 3 Reset button 4 Test button Important safety feature. The plug of the power cord contains a fuse as a safety feature to protect the cooling unit from damage. The fuse in the plug end of the power cord can trip if a power surge or a power outlet problem occurs. If pressing the reset button does not return the cooling unit to service, contact for assistance. Electrical Hazard: A qualified electrician should be contacted to correct electrical problems originating from the power outlet. InRoom SC 60 Hz User Manual Installation Location ON/OFF MODE SLEEP FAN TEMP TIME InRoomSC > 500 (20)> 500 (20) na3362a Dimensions are shown in mm (in). Requirements When deciding where to locate the cooling unit, consider cooling needs, air flow, and the location of the electrical outlet. The cooling unit can be no more than 2.4 m (8 ft) from the electrical outlet, condenser intake and exhaust access. Cooling needs. Position the cooling unit as close as possible to the main heat source that requires cooling. Air flow. Position the rear of the cooling unit at least 500 mm (20 in) away from a wall or other equipment. Location of electrical outlet. Place the cooling unit no farther than 2.4 m (8 ft) from a dedicated 120V, 60Hz, 15A branch circuit receptacle. Electrical Hazard: Do not use extension cords with this equipment. Using an extension cord reduces circuit protection and will void the warranty. Caution: To help avoid loss of cooling, only connect this equipment to a single-outlet dedicated circuit. InRoom SC 60 Hz User Manual 10 InRoom SC 60 Hz User Manual Exhaust Duct Assembly Dry Mode. Exhaust air must be allowed to return to the room in order for dehumidification to take place. Do not connect the exhaust hose to vent it outside the room. Continuous drainage for the condensate drain pan must be provided or it will fill up and the unit will automatically shut down until it is emptied. Cool Mode. Exhaust air must vent outside the room when using the cool mode. Note: Leave the door to the room slightly ajar to equalize pressure to improve ventilation. Exhaust kit Item Description Item Description 1 Exhaust cover 4 Ceiling connector end of exhaust hose 2 Ceiling adapter - 596 to 914 mm (23.5 to 36 in) 5 Exhaust vent of portable cooling unit 3 Phillips head screw ST 4.2 x 9.5 (2) 6 Flange connector end of exhaust hose ON/OFFMODE SLEEP FAN TEMP TIME InRoom SC MODE TIMER FAN SEND SLEEP DRY Hr. Min ON/OFF + °F - °F na3415a Installation. Exhaust air can be vented to the outside through the ceiling. The cooling unit should be positioned a minimum of 500 mm (20 in) from any wall; either at the back or on the sides. In a dropped ceiling, the ceiling adapter can be installed in place of one of the ceiling tiles. 1. Position the end of the exhaust hose so the small t...
Ce manuel est également adapté pour les modèles :Climatiseurs - INROOM SC ACPSC3500 (1.09 mb)