Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions Amcor, Modèle 15KE-410

Fabricant : Amcor
Taille : 681.04 kb
Nom Fichier : 1160e3da-48c5-4b41-ad9b-f04532cd1e50.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximise this product’s performance. For over 50 years Amcor has specialised in complete indoor environmental control, manufacturing and marketing; dehumidifiers, portable air conditioners, coolers, air purifiers, ionisers and aroma therapy scent diffusers. These world class products incorporate the latest technological developments. THANK YOU IMPORTANT! • The unit is designed for indoor operation. • Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet. • The installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician. • The air conditioner is safe. However, as with other electrical appliances, use it with care. • Keep out of the reach of children. • Do not clean the air conditioner by spraying it or immersing it in water. • Do not insert any object into the opening of the air conditioner. • Disconnect it from the mains before cleaning the unit or any of its components. • Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licensed electrician. • Don’t lift or move by pushing the air conditioner at the rear, but always at the front side. 3 GB • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. WARNING Close to a naked flame Inside unit exposed to the weather outdoors Near water If the power cable wires are frayed or cut When small children may be left unattended If an extension lead may become overloaded Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals Where there is a risk of interference by foreign objects This products is not made for DIY repair If there is a risk of liquid falling on the unit Do not use your air conditioner under the following conditions: 5 GB CONTROL PANEL ON / OFF Swing Increase Decrease Mode Ionizer Fan Sleep mode Timer Clock/ Cooling Fan Timer Temperature Timer Ionizer settings 6 GB INSTALLATION WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another. In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – To place the loose filters in the filter holder. • Take the filter holder out of the air conditioner. • Open the filter holder and place the active carbon filter (black) in the filter holder. • Place the filter fixing component back in the holder. • Place the filter holder back in the air conditioner. – Do not operate the unit inside the bathroom, shower, or in any other very humid environment. – Connect the hose to the unit by turning it clockwise (at least 5 turns). – Similarly, connect the hose to the slide bar connector as far as possible. – Place the telescopic slide bar in the open window or door and adjust the length to fill as much open space as possible. – Put the slide bar connector in the opening in the telescopic slide bar. – Close the window or door as much as possible to prevent outside air entering the room. – Ensure that the slide bar connector has a free flow outside. IMPORTANT! The flexible exhaust hose can be extended from 500 to 1500 mm for mounting. This length has been designed especially according to the specifications of the air conditioner. Do not use an extension or exchange for a different hose as that may lead to malfunctioning. The exhaust air must flow freely, any blockage can lead to overheating of the air conditioner. Take care to prevent any sharp bow or bend in the exhaust. 7 GB ON/OFF Press to switch the unit on or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour. Press momentarily, the 2 right digits of the 4 digits will flash. Press or to adjust the minutes of the clock. Press the -button for 3 seconds again to activate the clock. Setting the temperature If you want to change the set temperature press the or -button. The 2 digit display will indicate the set temperature. Note: Reaching the set temperature depends on the room and outdoor climatic conditions. Mode Pressing the -button to switch the operating mode between 'cooling' and 'fan ...

Ce manuel est également adapté pour les modèles :
Climatiseurs - 9KE-410 (681.04 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories