Log:
Évaluations - 2, GPA: 4 ( )

Instructions Carrier, Modèle 38AE014

Fabricant : Carrier
Taille : 293.47 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


All other operations should be performed by trained service personnel. When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging and setting bulky equipment. ELECTRICSHOCKHAZARDSeparatepowersources(mainandcontrolpowercircuits)areusedfortheseunits.Besurebothmainandcontrolpowercircuitsaredisconnectedbeforeservicing. INSTALLATION Step 1 — Complete Pre-Installation Checks UNCRATE UNIT — Remove unit packaging except for the top skid assembly, which should be left in place until after the unit is rigged into its final location. INSPECT SHIPMENT — File claim with shipping company if shipment is damaged or incomplete. CONSIDER SYSTEM REQUIREMENTS • Consult local building codes and National Electrical Code (NEC, U.S.A.) for special installation requirements. • Allow sufficient space for airflow clearance, wiring, refrigerant piping, and servicing unit. See Fig. 1. See Fig. 2 for unit component locations. • Locate unit so that outdoor coil (condenser) airflow is unrestricted on all sides and above. • Unit may be mounted on a level pad directly on the base channels or mounted on raised pads at support points. See Table 1A-1D for unit operating weights. See Table 2 for weight distribution based on recommended support points. NOTE: If vibration isolators are required for a particular installation, use the data in Table 2 to make the proper selection. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 111 Catalog No. 563-746 Printed in U.S.A. Form 38A-4SI Pg 1 4-94 Replaces: 38AE-17SI Tab 3a 2a LEGEND NOTES: 1. SERVICE AREAS — Allow 3 ft (914) on both sides A— 11.4-in. (32) diameter knockout for 5.8-in. (16) ODM liquid line connection and 2 ft (610) on both ends of unit for servicing. B— 13.4-in. (44.5) diameter knockout for suction line connections of 11.8 in. (28.6) 2. Dimensions in ( ) are in millimeters. (38AE012), 13.8 in. (35) (38AE014,016), 15.8 in. (41) (38AKS024) C— 7.8-in. (22.2) diameter knockout for control power D— 2-in. (50.8) diameter knockout for unit power Certified dimension drawings are available on request. Fig. 1 — Dimensions (ft-in.) 2 1 2 3 4 5 6 7 12 11 10 9 8 LEGEND 1 — Low-Voltage Fuse 5 — No. 2 Fan 9 — Compressor 2 — No. 1 Fan 6 — Terminal Block 1 (Unit Power) 10 — Low-Pressure Switch 3 — High-Pressure Switch 7 — Terminal Block 2 (Control Power) 11 — Hot Gas Bypass Piping Stub (3.8-in. ODM) 4 — Circuit Breakers 8 — Wraparound Coil 12 — Muffler Fig. 2 — Component Locations (Typical — 38AE Shown) 3 Table 1A — Physical Data (English, 60 Hz) UNIT 38AE012 38AE014 38AE016 38AKS024 OPERATING WEIGHT (lb) 732 779 789 900 REFRIGERANT* R-22 COMPRESSOR Speed (Rpm) Reciprocating, Semi-Hermetic 1750 No. Cylinders 6 6 6 4 Model No. 06DD824 06DD328 06DD537 06E4250 Oil (pt) 10 10 10 15.5 Crankcase Heater Watts Unloader Setting (psig) Load Unload 125 125 125 70±1 60±2 180 OUTDOOR-AIR FANS No. ...Rpm Axial Flow, Direct Drive 2...1075 Diameter (in.) Motor Hp 24 24 24 1.2 26 Nominal Total Airflow (Cfm) 8800 8800 8800 11,000 OUTDOOR COIL Face Area (sq ft) Storage Capacity (lb)† 27.2 29.2 40.3 39.8 39.8 CONTROLS Pressurestat Settings (psig) High Cutout 395±10 Cut-in 295±10 Low Cutout 29±4 Cut-in. 60 +15, –0 FUSIBLE PLUG (F) 200 PIPING CONNECTIONS (in. ODM) Suction Liquid 11.8 13.8 13.8 15.8 5.8 Unit is factory supplied with holding charge only. †Storage capacity is measured at liquid saturated temperatures of 125 F for 38AE012, 123 F for 38AE014, and 130 F for 38AE016 and 38AKS024. Table 1B — Physical Data (SI, 60 Hz) UNIT 38AE012 38AE014 38AE016 38AKS024 OPERATING WEIGHT (kg) 333 354 359 408 REFRIGERANT* R-22 COMPRESSOR Speed (r/s) Reciprocating, Semi-Hermetic 29.2 No. Cylinders 6 6 6 4 Model No. 06DD824 06DD328 06DD537 06E4250 Oil (L) 4.73 4.73 4.73 7.33 Crankcase Heater Watts Unloader Setting (kPa) Load Unload 125 125 125 483 ± 6.9 414 + 103, –0 180 OUTDOOR-AIR FANS No. ...r/s Axial Flow, Direct Drive 2...17.9 Diameter (mm) Motor Hp 610 610 610 1.2 661 Nominal Total Airflow (L/s) 4153 4153 4153 5566 OUTDOOR COIL Face Area (sq m) Storage Capacity (kg)† 12.4 2.71 18.3 18.1 18.1 CONTROLS Pressurestat Settings (kPa) High Cutout 2724 ± 68.9 Cut-in 2034 ± 68.9 Low Cutout 200 ± 27.6 Cut-in 414 + 103, –0 FUSIBLE PLUG (C) 93.3 PIPING CONNECTIONS (in. ODM) Suction Liquid 11.8 13.8 13.8 15.8 5.8 *Unit is factory supplied with holding charge only. †Storage capacity is measured at liquid saturated temperatures of 51.7 C for 38AE012, 50.6 C for 38AE014, and 54.4 C for 38AE016 and 38AKS024. 4 Table 1C — Physical Data (English, 50 Hz) UNIT 38AE012 38AE014 38AE016 38AKS024 OPERATING WEIGHT (lb) 732 779 789 900 REFRIGERANT* R-22 COMPRESSOR Speed (Rpm) Reciprocating, Semi-Hermetic 1460 No. Cylinders 6 6...

Ce manuel est également adapté pour les modèles :
Climatiseurs - 38AE012 (293.47 kb)
Climatiseurs - 38AE016 (293.47 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories