Log:
Évaluations - 3, GPA: 3.3 ( )

Instructions York, Modèle 14.5 SEER TCGF60

Fabricant : York
Taille : 339.18 kb
Nom Fichier : 061a1c4c-1646-423f-be80-068a9e4e2d9a.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Variable speed furnaces have B.O.D (Blower on Delay) standard. Johnson Controls Unitary Products 413432-YTG-A-0608 ACCESSORIES Refer to Price Manual for specific model numbers. HARD START KIT - Required when using TXV indoor coil. Also, provides increased starting torque for areas with low voltage. Model Source 1 Kit numbers 24 S1-2SA06721706 30 S1-2SA06705906 36 S1-2SA06708906 42 S1-2SA06708806 48 S1-2SA06708806 60 S1-2SA06707906 OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. TYPICAL INSTALLATION ROOM THERMOSTATS -A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1H/1C, manual changeover electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS* UNIT MODEL (dBA) 24 TBD 30 TBD 36 TBD 42 TBD 48 TBD 60 TBD * Rated in accordance with ARI 270-95 Standards. THERMOSTATSEALOPENING(S)WITHPERMAGUMOREQUIVALENTTOINDOORCOILTOFURNACEORAIRHANDLERTERMINALBLOCKNECCLASS2WIRINGNECCLASS1WIRINGALLOUTDOORWIRINGMUSTBEWEATHERPROOF. CONTROLACCESSPANELWEATHERPROOFDISCONNECTSWITCHMINIMUM18”SERVICEACCESSCLEARANCEONONESIDE60”OVERHEADCLEARANCE6”CLEARANCEAROUNDPERIMETERNOTE: TYPICAL FIELD WIRING ALLFIELDWIRINGTOBEINACCORDANCEWITHELECTRICCODE(NEC)AND/ORLOCALCODESPOWERWIRING208/230-1-60CONTACTORTERMINALSCOILGND. LUGCYRGWYRGWPOWERWIRINGCONTROLWIRINGFACTORYWIRING24VOLTCONTROLWIRINGMINIMUM18GA.WIRE(NECCLASS2) FURNACEORAIRHANDLERTERMINALBLOCKROOMTHERMOSTATCONDENSINGUNITALLOUTDOORWIRINGMUSTBEWEATHERPROOF.USECOPPERCONDUCTORSONLY. TERMINALWISONLYREQUIREDONSYSTEMSWITHHEAT. * * Johnson Controls Unitary Products 413432-YTG-A-0608 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGF24S41S1 INDOOR COIL MODEL NO. FC/MC/PC32 CONDENSING ENTERING AIR TEMPERATURE IDCFM 600 800 1000 ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 65 T.C. 21.8 23.8 23.8 25.7 27.7 23.9 25.4 25.3 27.6 29.5 26.1 27.1 26.9 29.4 31.4 S.C. 16.3 16.3 16.3 16.1 14.4 16.3 16.3 16.3 16.2 15.3 16.3 16.3 16.3 16.3 16.2 KW 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 75 T.C. 21.0 23.0 22.9 24.9 26.8 23.1 24.6 24.4 26.6 28.6 25.3 26.1 25.9 28.4 30.4 S.C. 16.3 16.3 15.8 15.7 13.9 16.3 16.3 16.0 16.0 14.9 16.3 16.3 16.3 16.3 15.9 KW 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 85 T.C. 20.2 22.2 22.0 24.1 25.9 22.4 23.7 23.5 25.7 27.7 24.5 25.2 24.9 27.3 29.5 S.C. 16.3 16.3 15.2 15.3 13.4 16.3 16.3 15.8 15.8 14.4 16.3 16.3 16.3 16.3 15.5 KW 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 95 T.C. 19.5 21.4 21.2 23.3 25.0 21.6 22.8 22.6 24.8 26.8 23.7 24.2 23.9 26.3 28.5 S.C. 16.3 16.3 14.7 15.0 12.9 16.3 16.3 15.5 15.6 14.0 16.3 16.3 16.3 16.3 15.1 KW 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 105 T.C. 18.4 20.1 19.9 22.0 23.7 20.4 21.4 21.1 23.4 25.2 22.4 22.6 22.4 24.7 26.8 S.C. 16.3 15.9 14.0 14.2 12.2 16.3 16.1 15.2 15.3 13.3 16.3 16.3 16.3 16.3 14.4 KW 2.2 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.2 115 T.C. 17.4 18.8 18.6 20.7 22.3 19.3 19.9 19.7 21.9 23.7 21.2 21.0 20.9 23.1 25.1 S.C. 16.3 15.4 13.4 13.5 11.6 16.3 15.9 14.8 14.9 12.6 16.3 16.3 16.3 16.3 13.6 KW 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 125 T.C. 16.3 17.5 17.3 19.3 20.9 18.1 18.4 18.3 20.4 22.2 19.9 19.4 19.3 21.6 23.4 S.C. 16.3 15.0 12.7 12.8 10.9 16.3 15.7 14.5 14.6 11.9 16.3 16.3 16.3 16.3 12.9 KW 2.9 2.9 2.9 2.9 2.8 2.9 2.9 2.9 2.8 2.8 2.8 2.8 2.9 2.8 2.8 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Johnson Controls Unitary Products 413432-YTG-A-0608 Air Handler Coil T.C. S.C. KW -FC/MC/PC24 1.02 1.04 1.02 -FC/MC/PC30 1.02 1.04 1.02 -FC/MC/PC35 1.02 1.06 1.02 -FC/MC/PC36 1.02 1.06 1.02 -FC/MC/PC37 1.04 1.08 1.02 -FC/MC/PC43 1.03 1.08 1.02 -FC/MC/PC48 1.05 1.10 1.02 -HC24 0.99 1.00 1.02 -HC30 1.01 1.04 1.02 -HC36 1.02 1.06 1.02 -HC42 1.04 1.08 1.02 -HD24 1.04 1.07 1.02 -HD36 1.01 1.02 1.02 -HD48 1.05 1.07 1.02 -UC24 1.02 1.05 1.02 -UC30 1.02 1.05 1.02 AHP24 -1.01 1.04 1.01 AV24 -1.02 1.05 0.93 AV36 -1.05 1.09 0.93 F4FP030 -1.02 1.04 1.02 MA08B FC/MC24B 1.02 1.04 1.02 MV12B FC/MC24B 1.04 1.07 0.94 MA08B FC/MC30B 1.02 1.04 1.02 MV12B FC/MC30B 1.04 1.07 0.94 MA08B FC/MC35B 1.02 1.06 1.02 MV12B FC/MC35B 1.05 1.08 0.93 MV16C FC/MC35C 1.05 1.08 0.93 MA08B FC/MC36B 1.02 1.06 ...

Ce manuel est également adapté pour les modèles :
Climatiseurs - 14.5 SEER TCGF24 (339.18 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories