Facilité d'utilisation
(SET POINT temperature equals inlet air or room temperature.) The unit has been preset at the factory for continuous fan operation. • Temperature Scale Display DIP Switch The Temperature Scale Display DIP Switch changes the temperature(s) that are displayed to either °C or °F. The unit has been preset from the factory to display the temperature(s) in °F. NOTE: If you wish to change the fan mode operation (COOLOPERATE to COOLSTOP), and/or the Temperature Scale Display (°F to °C), contact your MovinCool reseller. 13 OPERATION (cont.) Emptying the Drain Tank During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. If a program is running, you must first press the Program RUN button. . Open the drain tank lid. . Pull the drain tank from the unit. . Remove the cap and empty the drain tank. CAP . Replace the cap and return the drain tank to the unit. . Close the drain tank lid. . If the Program RUN LED is flashing, press the COOL ON/OFF button to continue running the program. If the Program RUN LED is illuminated continuously, no further steps are necessary. If no program exists or the program was deactivated, press the COOL ON/OFF button to restart the unit. 14 OPERATION (cont.) Drain Pump Kit (Optional) (Office Pro 12 model ONLY) A drain pump kit (CPK-3) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. A B NOTE: The compressor will not operate while the drain pump is discharging water. • When the water level drops below level (B), the drain pump stops, and the compressor will restart. NOTE: If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation. NOTE: If the Fan Mode Control DIP Switch (see pg. 13) is set to the STOP position, the entire unit (including fan operation) will turn off whether due to the overflow Drain Switch or while the drain pump is discharging water. DISCHARGE HOSE DRAIN PUMP DRAIN PUMP RESERVOIR 15 OPERATION (cont.) DRAIN PUMP KIT (Optional) (Office Pro 24 model ONLY) A drain pump kit (CPK-5) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. • When the water level drops below level (B), the drain pump will stop. NOTE: If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation. NOTE: If the Fan Mode Control DIP Switch (see pg. 13) is set to the STOP position, the entire unit (including fan operation) will turn off due to the overflow Drain Switch. DISCHARGE HOSE DRAIN PUMP DRAIN PUMP RESERVOIR 16 DAILY INSPECTION & MAINTENANCE Emptying the Drain Tank To empty the drain tank, refer to instructions on page 14. Cleaning the Air Filters Clean the air filters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required. A dirty air filter reduces air output resulting in a decrease of the cooling capacity. Filter Removal Method (both models) . Turn the unit off by pressing the COOL ON/OFF button. If a program is running, you must first press the Program “RUN” button. . Remove the two air filters. NOTE: To remove the filters from the Office Pro models, open the front panel and side panel filter doors. On the front panel door, carefully remove the filter retainer from its clips by pulling on the retainer at those two points. On the side panel door, carefully remove the filter element from the Velcro® attachment points. RETAINER FILTER 17CLIP CLIPVELCRO® ATTACHMENT POINTS FILTER DAILY INSPECTION & MAINTENANCE (cont.) Filter Cleaning Method . Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash with a neutral detergent. . After the element has been cleaned, rinse with clean running water, allow to dry, then FILTER reinstall. In-Season/Off-Season Inspection & Maintenance ¦ In-Season . Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. . Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. . Check the air filters and drain tank. . Clean the outside of the unit(s) with a damp cloth or mild nonabrasive cleaner. ¦ Off-Season . Operate the unit in Fan Only mode for 8 hours. Note: Operation is necessary to dry out the inside of the unit. . Disconnect the power cord from the AC outlet. . Check the prongs and s...
Ce manuel est également adapté pour les modèles :Climatiseurs - OFFICE PRO 12 (1.85 mb)