Log:
Évaluations - 2, GPA: 4 ( )

Instructions Heat Controller, Modèle DMC24DB-1

Fabricant : Heat Controller
Taille : 3.49 mb
Nom Fichier : bdd10a7b-65b6-499c-8d6d-1a6be0e46cc5.pdf
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


Do not drink the water drained from the unit. • It is not sanitary and could cause serious health issues. Use a firm stool or ladder when cleaning or maintaining the air conditioner. • Be careful and avoid personal injury. Replace all the batteries in the remote. • There is risk of fire or explosion. Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. • They may burn or explode. If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. • The chemicals in batteries could cause burns or other health hazards. Disuse Prior to operation Prior to operation Preparing for operation 1. Contact an installation specialist for installation. 2. Connect the power cable between indoor unit and outdoor unit properly. 3. Use a dedicated circuit. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time. 2. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items. Cleaning and maintenance 1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. 3. When cleaning the unit, first make sure that the power and breaker are turned off. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit. Service For repair and maintenance, contact your authorized service dealer. Symbols Used in this Manual NOTICE This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. This symbol indicates special notes. 8 Room Air Conditioner Operating Instructions Operating Instructions Remote Controller 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTICE Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. Storage and Tips For Using the Remote Controller • The remote control may be stored mounted on a wall. • To operate the room air conditioner, aim the remote control at the signal receptor. • The remote control will operate the air conditioner at a distance of up to 7m(23ft). Owner's Manual 9 Operating Instructions 10 Room Air Conditioner Signal Receptor Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.) Operation Indication Lamps On/Off : Lights up during the system operation. Sleep Mode : Lights up during Sleep Mode Auto operation. Timer : Lights up during Timer operation. Defrost Mode Outdoor unit operation OUT DOOR : Lights up during Defrost Mode or Hot Start operation (Heat pump model only) : Lights up during outdoor unit operation.(Cooling model only) Desire temperature For cooling,dehumidification,heating modes it display Destired temperature indicator • Cooling : 18°C~30°C(64°F~86°F) • AI : Auto Operation • Dehumidification : 18°C~30°C(64°F~86°F) • Po : Jet Cool • Heating : 16~30°C(60°F~86°F) • Lo : Test Mode Operation indicating lamps Operating Instructions Remote Control Operation Controls Signal transmitter ON OFF CANCEL AUTO CLEAN SET 1 3 5 4 9 10 12 14 16 7 2 8 13 11 6 Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Flip-up door (opened) Heating Operation • Cooling Model( ), Heat Pump Model( ) 15 Operation Mode 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. SELECTION BUTTON SELECTION BUTTON 2. OPERATION MODE (Heat Pump) (Cooling Only) Used to select the operation mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. 5. JET COOL Used to start or stop the speed cooling/heating.(speed cooling/heating operates super high fan speed.) 6. CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. 7. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. (See page 18) 8. TIME SETTING BUTTONS Used to adjust the time. (See page 18) 9. TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 18) 10. SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. (See page 18) 11. AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. (See page 19) 12. ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 13...

Ce manuel est également adapté pour les modèles :
Climatiseurs - DMC36TB-1 (3.49 mb)
Climatiseurs - DMH24DB-1 (3.49 mb)
Climatiseurs - DMH36TB-1 (3.49 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories