Log:
Évaluations - 2, GPA: 4 ( )

Instructions Panasonic, Modèle CS-PA16KKD

Fabricant : Panasonic
Taille : 5.73 mb
Nom Fichier :
Langue d'enseignement: ruukenesfr
Aller à la télécharger



Facilité d'utilisation


Procedure of switching OFF/ON signal receiving sound: 1. Press and hold “AUTO OFF/ON” button for approximately 10 seconds until you hear double beep sound. 2. Repeat above step within 60 seconds , and then signal receiving sound will be switched OFF/ON. Procedure of switching OFF/ON auto restart control: 1. Press and hold “AUTO OFF/ON” button for approximately 15 seconds until you hear triple beep sound. 2. Repeat above step within 60 seconds , and then auto restart control will be switched. 8 AIR FILTERS • Clean the filters regularly. • Wash/rinse the filters gently with water to avoid damage to the filter surface. • Dry the filters thoroughly under the shade, away from fire or direct sunlight. • Replace any damage filter. TROUBLESHOOTING The following symptoms do not indicate malfunction. SYMPTOM CAUSE Mist emerges from indoor unit. > • Condensation effect due to cooling process. Water flowing sound during operation. > • Refrigerant flow inside the unit. The room has a peculiar odour. > • This may due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting. > • This helps to remove the surrounding odours. Operation is delayed a few minutes after restart. > • The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam. > • Condensation or evaporation occurs on pipes. Cracking sound during operation. > • Changes of temperature cause the expansion/contraction of the unit. The unit operates automatically when power is resumed after a power failure. > • This is the Auto Restart function of the unit. Operation will be restarted automatically under the previous operation mode when power is resumed as the operation is stopped due to power failure. • To cancel the Auto Restart Control, please refer to page 6. Power indicator blinks during heating operation and the indoor fan is stopped. > • The unit is in defrost mode, and the melted frost is drained from the outdoor unit. Indoor fan stops occasionally during heating operation. > • To avoid unintended cooling effect. Check the following before calling for servicing. SYMPTOM CHECK Cooling/Heating operation is not working efficiently. > • Set the temperature correctly. • Close all doors and windows. • Clean or replace the filters. • Clear any obstruction at the air inlet and air outlet vents. Noisy during operation. > • Check if the unit has been installed at an incline. • Close the front panel properly. Remote control does not work. (Display is dim or transmission signal is weak.) > • Insert the batteries correctly. • Replace weak batteries. The unit does not work. > • Check if the circuit breaker is tripped. • Check if timers have been set. The unit does not receive the signal from the remote control. > • Make sure the receiver not obstructed. • Certain fluorescent lights may interfere with signal transmitter. Please consult authorized dealer. 8 МЕРЫ ПРЕДОСТОРОЖНОСТИ Благодарим вас за приобретение кондицион...

Ce manuel est également adapté pour les modèles :
Climatiseurs - CU-PA16KKD (5.73 mb)
Climatiseurs - CU-PA12KKD (5.73 mb)
Climatiseurs - CS-PA12KKD (5.73 mb)
Climatiseurs - CU-PA7KKD (5.73 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories