Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Samsung, Modèle AQ09FCNSAM

Fabricant : Samsung
Taille : 5.51 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


• Even if Deodorizing and Anti-allergy filters are installed in an inverted position, it will not affect its filtration system. cleaning and maintaining _29 ENGLISH MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness. Periodical checks Refer to the following chart to maintain the air conditioner properly. Type Description Monthly Every 4 months Once a year Indoor unit Clean the air filter.(1) . Clean the condensate drain pan (2) . Thoroughly clean the heat exchanger (2) . Clean the condensate drain pipe (2) . Replace the remote control batteries.(1) .. Outdoor unit Clean the heat exchanger on the outside of the unit (2) . Clean the heat exchanger on the inside of the unit (2) . Clean the electric components with jets of air (2) . Verify that all the electric components are firmly tightened (2) . Clean the fan (2) . Verify that all the fan assembly is firmly tightened (2) . Clean the condensate drain pan (2) . The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc. (1) The described operations should be performed more frequently if the area of installation is very dusty. (2) These operations must always be performed by qualified personnel. For more detailed information, see the Installation Manual. 30_ cleaning and maintaining cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating. De-ice cycle The internal fan will be off to against cold air when the heat pump is heating. Anti-protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode. Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started. If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures. The internal fan is switched off automatically and restarted only after the de-ice cycle is completed. appendix _31 ENGLISH appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not operating immediately after it has been restarted. • Because of the protective mechanism, the appliance does not start operating immediately to keep the unit from overloading. The air conditioner will start in 3 minutes. The air conditioner does not work at all. • Check that the power plug is properly connected. Insert the power plug into the wall socket correctly. • Check if the circuit breaker is switched off. • Check if there is a power failure. • Check your fuse. Make sure it is not blown out. The temperature does not change. • Check if you selected Fan mode. Press the Mode button on the remote control to select another mode. The cool(warm) air does not come out of the air conditioner. • Check if the set temperature is higher (lower) than the current temperature. Press the Temperature ..or . button on the remote control to change the set temperature. Press the Temperature ..or . button to increase or decrease the temperature. • Check if the air filter is blocked by dirt. Clean the Air filter every two weeks. • Check if the air conditioner has just been turned on. If so, wait 3 minutes. The fan speed does not change. • Check if you selected Auto or Dry mode. The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode. Timer function does not set. • Check if you press the Power & Set/Cancel button on the remote control after you have set the time. Odors permeate in the room during operation. • Check if the appliance is running in a smoky area or if there is a smell entering from outside. Operate the air conditioner in Fan mode or open the windows to air out the room. The air conditioner makes a bubbling sound. • A bubbling sound may be heard when the refrigerant is circulating through the compressor. Let the air conditioner operate in a selected mode. Water is dripping from the air flow blades. • Check if the air conditioner has been cooling for an extended period of ti...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AVXWNH022EE (5.51 mb)
Climatiseurs - AVXWNH028EE (5.51 mb)
Climatiseurs - AVXWNH036EE (5.51 mb)
Climatiseurs - AVXWNH056EE (5.51 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories