Log:
Évaluations - 2, GPA: 3.5 ( )

Instructions Samsung, Modèle AQ09JWAN

Fabricant : Samsung
Taille : 8.16 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


(If applicable) . When using a wireless remote control, the distance should not be more than 7 meters from the air conditioner. (If applicable) . Do not place any materials so that children cannot step on it. . Do not connect the electric heater to the air conditioner or repair it with your discretion. . The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections. . Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. Keep children away from the unit. . Failure to observe the installation instruction, or use of the unit under conditions other than those indicated in the table 'Operating limit' of the unit installation manual, will immediately invalidate the unit warranty. E-5 ENGLISH . Before throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons. . When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environments. . Please recycle or dispose of the packaging material for this product in an environmentally responsible manner. DISPOSING THE UNIT WARNING . Install the air conditioner avoiding direct sunlight or heater, especially water. . Install the outdoor unit so as to let the discharged air out properly. Avoid a place that may disturb your neighbor by noise. . Install the drain hose to let the water run safely and correctly. WHEN INSTALLING CAUTION E-6 . Disconnect the circuit breaker when you don’t use the air conditioner for a long time to save energy. . Contact the service center or manufacturer if you want to repair the air conditioner. . Contact the service center after turning off the air conditioner if strange noise is heard, burning smell or smoke blow. REGARDING POWER SOURCE . Do not open the front grille during operation. . Avoid cold and hot air reaching to person, pet or a plant directly for a long time. . Avoid the water from getting into the air conditioner. DURING OPERATION . Do not use the air conditioner for a long time in a closed room or in a place where there’s a baby or an old person. . Do not step on the air conditioner or put heavy object on it. . Do not drink the water from the air conditioner. CAUTION E-7 ENGLISH . Do not touch the pipes connected to the air conditioner. . Do not use the air conditioner to maintain the machine, food, pet, plant or cosmetics. . Do not give excessive shock to the air conditioner. DURING OPERATION . The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance. . The maximum input power & current is measured according to the IEC standard and the input power & current is measured according to the ISO standard. OTHERS . Be sure that the air filter not to be exposed to direct sunlight. . Do not clean the air conditioner by spraying water directly or with benzene, thinner or alcohol. . The surface of the heat exchanger is sharp, so be careful of it when cleaning. . Turn off the air conditioner and if the fan stops to operate, clean the air conditioner. . Clean the air filter every 2 weeks. . Be sure to insert the air filter. CAUTION . All of the manufacturing and packaging materials used for your new appliance are compatible with the environment and can be recycled. . Dispose of the packaging material in accordance with the local requirements. E-8 Name of Each Part The design and shape can be changed according to the model. Indoor Unit Air filter (under the grille) Air flow blades (outlet) Air Inlet Temperature sensor Power(On/Off) button Operation indicator (GREEN) Timer indicator (GREEN) Turbo indicator (RED) Power(On/Off) button AQ..F. Series AQ..J. Series AQ..W. Series E-9 ENGLISH Outdoor Unit AQ09...Series Air Outlet Connection Valve (Inside) Air Inlet (Rear) Outdoor Unit AQ12...Series Outdoor Unit AQ18...Series Outdoor Unit AQ24...Series Air Outlet Connection Valve (Inside) Air Inlet (Rear) Air Outlet Connection Valve (Inside) Air Inlet (Rear) Air Outlet Connection Valve (Inside) Air Inlet (Rear) E-10 Remote Control-Buttons and Display Remote control transmission indicator Mode selection button (AUTO, COOL, DRY, FAN, HEAT) Turbo button Swing button On Timer button Off Timer button On/Off & Timer Set/Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Good Sleep mode indicator Turbo function indicator Fan speed indicator Air flow direction On Timer indicator Off Timer indicator Battery discharge indicator Good Sleep button Operating mode indicator ( AUTO, COOL, DRY, FAN, HEAT) E-11 ENGLISH Inserting the Remote Control Batteries You must insert or replace the remote control batteries when: . You purchase the air condition...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AQ09FAN (8.16 mb)
Climatiseurs - AQ12FAN (8.16 mb)
Climatiseurs - AQ12FBN (8.16 mb)
Climatiseurs - AQ12FBX (8.16 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories