Fabricant : LG
Taille : 2.83 mb
Nom Fichier :
|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
TYPE : Floor Standing Type ENGLISHITALIANOESPANOLFRANCAISDEUTSCHOWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Floor Standing Type ENGLISHITALIANOESPANOLFRANCAISDEUTSCH The equipment complies with requirements of the Technical Regulation, in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment. P/NO : 3828A30142U Floor Standing Type Air Conditioner Owner.s Manual TABLE OF CONTENTS Safety Precautions................................................................................................................3 Operating Instructions..........................................................................................................7 - Features and Specifications..............................................................................................7 - Indoor Unit Controls and Indicators...................................................................................8 - How to use the Operation Mode Button ............................................................................9 - How to use the Fan speed Button.....................................................................................9 - Cooling Operation Mode .................................................................................................10 - Soft Dry Operation...........................................................................................................11 - Heating Operation Mode .................................................................................................12 - Electric Heater Operation Mode......................................................................................13 - OFF Timer Setting Procedure(OFF TIMER Setting, or CANCEL) ..................................14 - Fan Operation Mode .......................................................................................................15 - Airflow Direction Procedure.............................................................................................15 - Child Lock Operation Procedure .....................................................................................16 Maintenance and Service ...................................................................................................17 - During the season ...........................................................................................................17 - When the air conditioner is not going to be used for a long time. ...................................17 - Operation Tips.................................................................................................................17 - Troubleshooting ..............................................................................................................18 2 Floor Standing-Type Air Conditioner Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ¦ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. ENGLISH WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ¦ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING ¦Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. • There is risk of fire or electric shock. Install the panel and the cover of control box securely. • There is risk of fire or electric shock. Do not modify or extend the power cable. • There is risk of fire or electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. • Do not disassemble or repair the product. There is risk of fire or electric shock. Always install a dedicated circuit and breaker. • Improper wiring or installation may cause fire or electric shock Do not install, remove, or reinstall the unit by yourself (customer). • There is risk of fire, electric shock, explosion, or injury. Always ground the product. • There is risk of fire or electric shock. Use the correctly rated breaker or fuse. • There is risk of fire or electric shock. Be cautious when unpacking and installing the product. • Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator. Owner's Manual 3 Safety Precautions For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. • Moisture may condense and wet or damage furniture. Do not plug or unplug the power supply plug during operation. • There i...