Fabricant : Samsung
Taille : 5.06 mb
Nom Fichier :
|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
without motion 3 channel 3 1 2°C 1 Oil return or Noise decreasing in defrost mode 2 Turn out in 60min. without motion 3 Turn out in 120min. without motion 4 Turn out in 180min. without motion 5 Turn out in 30min. without motion or *advanced function 2 5°C 6 Turn out in 60min. without motion or *advanced function 7 Turn out in 120min. without motion or *advanced function 4 channel 4 8 Turn out in 180min. without motion or *advanced function *Advanced function: Controlling cooling/heating current or power saving with motion detect. . 05 series installation option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 0 5 Use of Auto Change Over for HR only in Auto mode (When setting SEG3) Standard heating temp. Offset (When setting SEG3) Standard cooling temp. Offset (When setting SEG3) Standard for mode change Heating > Cooling SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 (When setting SEG3) Standard for mode change Cooling > Heating (When setting SEG3) Time required for mode change Compensation option for Long pipe or height difference between indoor units - - SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 2 - - - - - SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 3 - - - - - Setting an indoor unit address and installation option . 05 series installation option(Detailed) Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE Use of Auto Change Over for HR only in Auto mode (When setting SEG3) Standard heating temp. Offset (When setting SEG3) Standard cooling temp. Offset (When setting SEG3) Standard for mode change Heating > Cooling Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 0 5 0 Follow product option 0 0 0 0 0 1 1 Use Auto Change Over for HR only 1 0.5 1 0.5 1 1.5 2 1 2 1 2 2 3 1.5 3 1.5 3 2.5 4 2 4 2 4 3 5 2.5 5 2.5 5 3.5 6 3 6 3 6 4 7 3.5 7 3.5 7 4.5 Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE (When setting SEG3) Standard for mode change Cooling > Heating (When setting SEG3) Time required for mode change Compensation option for Long pipe or height diffference between indoor units Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details 1 0 1 0 5 min. 0 Use default value 1 1.5 1 7 min. 1 1) Height difference1) is more than 30m or 2) Distance2) is longer than 110m 2 2 2 9 min. 3 2.5 3 11 min. 4 3 4 13 min. 2 1) Height difference1) is 15~30m or 2) Distance2) is 50~110m 5 3.5 5 15 min. 6 4 6 20 min. 7 4.5 7 30 min. 1) Height difference : The difference of the height between the corresponding indoor unit and the indoor unit installed at the lowest place. For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the option "1". 2) Distance : The difference between the pipe length of the indoor unit istalled at farthest place from an outdoor unit and the pipe length of the corresponding indoor unit from an outdoor unit. For example, when the farthest pipe length is 100m and the corresponding indoor unit is 40m away from an outdoor unit, select the option "2". (100 - 40 = 60m) SEG 3, 4, 5, 6, 8, 9 additional information When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows. Heating Thermo Off Cooling Thermo On Heating Thermo On Cooling Thermo Off Standard temp. for Heating > Cooling Temp. c b Standard temp. for Cooling C B Ts D A Set temp. for Auto mode a Standard temp. for Heating d Standard temp. for Cooling > Heating A : Set with SEG4(.C) B : Set with SEG5(.C) C : Set with SEG6(.C) D : Set with SEG8(.C) Cooling/Heating mode can be changed when Thermo Off status is maintained during the time with SEG9. Changing a particular option You can change each digit of set option. Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE The option mode you want to change The tens’ digit of an option SEG you will change The unit digit of an option SEG you will change The changed value Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 0 D Option mode 1~6 Tens’ digit of SEG 0~9 Unit digit of SEG 0~9 The changed value 0~F • When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’. • When changing a digit of indoor unit installation option, set the SEG3 as ‘2’. Ex) When setting the ‘buzzer control’ into disuse status. Note Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE The option mode you want to change The tens’ digit of an option SEG you will change The unit digit of an option SEG you will change The changed value Indication 0 D 2 1 7 1 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 (Dutch) (French) BOSNIA 051 133 1999 BULGARIA ...
Ce manuel est également adapté pour les modèles :Climatiseurs - AM036FNJDEH/EU (5.06 mb)
Climatiseurs - AM056FNJDEH (5.06 mb)