Log:
Évaluations - 0, GPA: 0 ( )

Instructions Samsung, Modèle AM050FNKDEH

Fabricant : Samsung
Taille : 6.62 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at EN ES FR IT PT DB68-03715A(1)DE Features of your new product Ventilator The product helps save energy and drive down operation costs of heaters and coolers by recycling thermal energy (energy load) efficiently. Interlocked operation with DVM Controls of interlocked operation for energy saving, One remote controller can be used with air conditioners. Mounted for DX-coil unit for outdoor air treatment This improves the dry and cooling effect in the summer and humidifying effect in the winter. Humidity Control Fresh air conditions are guaranteed by recovering moisture in winter while exhausting it in summer. The high efficiency Humidifier element can be mounted.(Optional product) Low Noise and Low Power With highly efficient motor and optimized system design, operation noise and electric consumption is minimized. The high efficiency filter This protects the heat exchange element and cleans the polluted outdoor air before it enters the indoor room. Operation at Cold Area Optimized automatic ventilation operation is conducted to prevent condensation and air volume reduction. Clean-UP operation Prevent the odor and dust of other places such as bathroom and kitchen from entering inside by making supply air greater than the exhaustion air. (You can reverse this procedure to make the exhaustion air bigger than the supply air.) How to use this unit This unit should be used with air conditioners. Air conditioning is impossible only by this unit, because this unit does not have temperature control function. (It’s capacity is too small in order to control the room temperature to the whole) And should be operated in combination with standard indoor units. (Interlocked operation) Independent operation is possible, however, temperature setting by remote controller is impossible. In this ON/OFF operation by thermostat depends on factory setting, however, this value is changeable by installation/service mode on site. Model selection should be done not by cooling capacity but by ventilating air flow rate. Refer to following capacities when using the product with outdoor unit: AM050FNKDEH -3.6kW, AM100FNKDEH -7.1 kW 3 ENGLISH USING PARTS Safety precautions ................................................................................................................................................................................................................................ 4 Checking before use ............................................................................................................................................................................................................................ 8 Checking the name of the parts .................................................................................................................................................................................................. 11 Basic operation .................................................................................................................................................................................................................................... 16 Cleaning and maintaining the unit ............................................................................................................................................................................................ 19 Maintaining your product .............................................................................................................................................................................................................. 23 Appendix ................................................................................................................................................................................................................................................ 24 INSTALLATION PARTS Safety precautions ............................................................................................................................................................................................................................. 26 Accessories ............................................................................................................................................................................................................................................ 29 Selecting the installation location .............................................................................................................................................................................................. 29 Indoor unit installation .................................................................................................................................................................................................................... 31 Purging the un...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AM100FNKDEH (6.62 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories