Log:
Évaluations - 0, GPA: 0 ( )

Instructions Samsung, Modèle AQV09UGAN

Fabricant : Samsung
Taille : 6.35 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


operating basic function SELECTING OPERATION MODE Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air. Dry mode makes the air feel refreshing in a humid climate. 1. Turn on the air conditioner. Press the Power button on the remote control. 2. Set the operating mode. Press the Mode button on the remote control until Dry mode indicator appears on the remote control display. The air conditioner operates in Dry mode and automatically adjust the fan speed to Auto. Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. 3. Set the temperature. Press the Temp ..or . button on the remote control to increase or decrease the desired temperature. You can set the desired temperature between the range of 18.C~30.C. You can increase/decrease the temperature by 1.C. • While you are using the remote control, make sure correct indicator which matches your selection appears on the remote control display. • Air flow can be adjusted manually (see page 19 for instructions). 16_ operating Fan Fan mode can be selected to ventilate your room. Fan mode will be helpful to refresh the stale air ENGLISHin your room. 1. Turn on the air conditioner. Press the Power button on the remote control. 2. Set the operating mode. Press the Mode button on the remote control until Fan mode indicator appears on the remote control display. The air conditioner operates in Fan mode and circulate the indoor air. Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. 3. Set the fan speed. Press the Fan .or . button on the remote control to set the desired fan speed. Each time you press the Fan .or . button, fan speed will change in order of Low, Medium and High. • While you are using the remote control, make sure correct indicator which matches your selection appears on the remote control display. • Air flow can be adjusted manually (see page 19 for instructions). operating _17 operating basic function SELECTING OPERATION MODE Heat The air conditioner heats as well as cools. Warm your room with this versatile appliance in the 18_ operating cold of winter. 1. Turn on the air conditioner. Press the Power button on the remote control. 2. Set the operating mode. Press the Mode button on the remote control until Heat mode indicator appears on the remote control display. The air conditioner operates in Heat mode and warms your room. Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. 3. Set the temperature. Press the Temp ..or . button on the remote control to increase or decrease the desired temperature. You can set the desired temperature between the range of 16.C~30.C. You can increase/decrease the temperature by 1.C. 4. Set the fan speed. Press the Fan .or . button on the remote control to set the desired fan speed. If room temperature reaches desired value, heating will stop for a while. • Each time you press the Fan .or . button, fan speed will change in order of Auto, Silence,Low, Medium and High. • Fan may not operate for about 3~5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up. • Air flow can be adjusted manually (see page 19 for instructions). • Since the air conditioner heats the room by taking heat energy from outdoor air, the heating capacity may decrease when outdoor temperature is extremely low. Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently. • Silence mode( ) makes the noise quieter during operating the indoor unit in the Heat mode. ADJUSTING THE AIR FLOW DIRECTION Air flow can be directed to your desired position. Vertical air flow Air flow blades move up and down. ENGLISH1. Press the Air swing button on the remote control. Air swing indicator will be on and air flow blades move up and down continuously to circulate the air. Press the Air swing button on the remote control again, to keep the air flow direction in a constant position. Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken. 1. Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer. Be extremely careful with your fingers while adjusting the Horizontal air flow direction. There is a potential risk of personal injury when the unit is mishandled. CAUTION Blade pin lever operating _19 using advanced functions USING THE TURBO FUNCTION Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan speed for 30 minutes. 1. Turn on the air conditioner. Press the Power button on the remote control. 2. Set the operating mode. Press the Turbo button on the remote control until Turbo indicator appears on the remote control display. The air conditioner operates in Auto fan speed and automatically adjusts the temperature according...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AQV09UGAX (6.35 mb)
Climatiseurs - AQV12UGAN (6.35 mb)
Climatiseurs - AQV12UGAX (6.35 mb)
Climatiseurs - AQV18UGAN (6.35 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories