CL . is displayed in the remote controller for about three seconds. But the Room Temperature function is operated in spite of child lock mode. 2. To cancel the Child-Lock Function Press the Timer button and Minute Set button for three seconds. Then the child-lock mode is cancelled and the preselected mode is displayed in the remote controller. 24 Cassette-Type Air Conditioner Operating Instructions Operation unit JET Humidify AUTO Program set Room Temp MED LO Heater Defrost Filter Preheat Out door Time Timer On Set no. Time Off 01 03 05 07 09 11 13 15 17 19 21 23 Timer Cancel Program Week Hour Min Holiday SET/CLR RESET Plasma ZONE 1 2 3 4 AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION HI Plasma Press the On/Off button. The 1 unit will respond with a beep. Open the door on the remote control. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again. 2 Set the fan speed again with door of the remote control closed. You can select the fan speed in four steps-low, medium, high or Auto. Each time the button is pressed, the fan speed mode is shifted. . Air purifying operation (PLASMA) with cooling, heating or any other operations. 3 Tips for Filter sign LED 1. Filter sign lamp (LED) is ON. 2. If LED indicating filter sign lamp is ON, clean the filter. 3. After cleaning the filter, press the Timer button and . button of wired remote controller at the same time for 3 sec. Then filter sign LED is OFF. PLASMA Purification Operation (Optional) Owner's Manual 25 Operating Instructions Forced Operation Auto Restart Function High. Speed Forced operation. (Tact switch) In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. Heat pump Model Cooling Model Room Temp. . set Temp.-2°C Room Temp. < set Temp.-2°C Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly. Operating mode Cooling Cooling Heating Indoor FAN Speed High set available set available Setting Temperature 22°C set available set available Operation procedures when the remote control can't be used. Press the tact switch (Forced operation) for 2 seconds. If you want to stop operation, press again the tact switch. In case the power comes on again after power failure on the Forced Operation mode, the operating conditions are automatically set as follows: During Forced Operation, the initial mode continues. 26 Cassette-Type Air Conditioner Maintenance and Service CAUTION Before performing any maintenance, turn off the main power to the system. Indoor Unit Outdoor Unit Maintenance and Service Grille, Case and Remote Control . Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning the indoor unit. NOTICE Remove the Air filters. ¦ Take hold of the tab and pull slightly forward to remove the filter. ¦ Never use any of the followings: • Water hotter than 40°C. Could cause deformation and/or discoloration. • Volatile substances. Could damage the surfaces of the air conditioner. The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. NOTICE Air Filters The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit. It may cause an injury. Clean dirt from the air filter using a vacuum cleaner or washing with water. ¦ If dirt is conspicuous, wash with a neutral detergent in lukewarm water. ¦ If hot water (50°C or more) is used, it may be deformed. After washing with water, dry well in the shade. ¦ Do not expose the air filter to direct sunlight or heat from a fire when drying it. Install the air filter. Benzene SCOURING CLBARGER SINNER Air Outlet Air Intake. (side, rear) Connecting Wire Drain Hose Connection Pipe Power Wire Anti-bacteria filter Air Outlet Air Intake Remote Controller Air Filter Rack 1 2 3 4 Maintenance and Service When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. 1. Operate the air conditioner at the following settings for 2 to 3 hours. • Type of operation: Fan operation mode.(Refer to page 21.) • This will dry out the internal mechanisms. 2. Turn off the breaker. CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories