Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions York, Modèle AFFINITY 360101-XTG-A-0108

Fabricant : York
Taille : 444.67 kb
Nom Fichier : 125dea73-7ed1-4f40-966e-1397cb464930.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity ALL SENSIBLE CAPACITIES Johnson Controls Unitary Products 360101-XTG-A-0108 TABLE 7: COOLING CAPACITIES - 3-1/2 TON (DEB042) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1,050 CFM 1,225 1,400 1,575 1,750 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F Net Cap MBH 40.7 39.0 36.5 34.1 42.0 40.3 37.7 35.2 43.3 41.6 38.8 36.3 43.9 42.1 39.3 36.8 44.4 42.6 39.8 37.2 Total Power Input kW 4.09 3.82 3.77 3.75 4.16 3.89 3.83 3.81 4.23 3.95 3.90 3.88 4.38 4.10 4.04 4.02 4.54 4.25 4.18 4.16 Sensible CapacityMBH1Entering DryBulb ° F 86 23.8 31.3 36.5 34.1 26.1 34.2 37.7 35.2 28.5 37.0 38.8 36.3 30.5 39.4 39.3 36.8 32.6 41.9 39.8 37.2 83 20.8 28.3 34.6 34.1 22.6 30.6 36.7 35.2 24.4 32.9 38.8 36.3 25.9 34.8 39.3 36.8 27.3 36.6 39.8 37.2 80 17.8 25.4 31.6 31.9 19.1 27.1 33.8 34.1 20.3 28.8 36.0 36.3 21.2 30.1 37.6 36.8 22.1 31.4 39.2 37.2 77 14.9 22.4 28.6 28.9 15.5 23.6 30.3 30.6 16.2 24.7 31.9 32.2 16.6 25.5 32.9 32.1 16.9 26.2 34.0 32.0 74 11.9 19.4 25.6 26.0 12.0 20.0 26.7 27.0 12.1 20.7 27.8 28.1 11.9 20.8 28.3 27.5 11.7 21.0 28.8 26.8 71 -16.4 22.7 23.0 -16.5 23.2 23.5 -16.6 23.7 24.1 -16.2 23.6 22.8 -15.8 23.6 21.6 68 -13.4 19.7 20.0 -12.9 19.6 20.0 -12.5 19.6 20.0 -11.5 19.0 18.2 -10.6 18.3 16.4 95 °F Net Cap MBH 38.7 36.7 34.0 32.7 40.1 38.1 35.2 33.9 41.6 39.4 36.5 35.2 42.1 39.9 36.9 35.6 42.6 40.3 37.4 36.0 Total Power Input kW 4.16 4.06 3.96 3.98 4.23 4.13 4.03 4.05 4.30 4.19 4.10 4.11 4.44 4.33 4.23 4.25 4.59 4.47 4.37 4.39 Sensible CapacityMBH1Entering DryBulb °F 86 23.0 30.4 34.0 32.7 25.4 33.3 35.2 33.9 27.8 36.3 36.5 35.2 29.9 38.3 36.9 35.6 32.0 40.3 37.4 36.0 83 20.0 27.4 33.2 32.7 21.9 29.8 34.9 33.9 23.7 32.2 36.5 35.2 25.2 34.1 36.9 35.6 26.7 36.0 37.4 36.0 80 17.0 24.4 30.3 30.4 18.3 26.3 32.6 32.8 19.7 28.2 35.0 35.2 20.6 29.5 36.2 35.6 21.5 30.8 37.4 36.0 77 14.0 21.4 27.3 27.5 14.8 22.7 29.1 29.3 15.6 24.1 30.9 31.1 15.9 24.8 31.5 30.9 16.3 25.6 32.1 30.8 74 11.0 18.4 24.3 24.5 11.3 19.2 25.5 25.7 11.5 20.0 26.8 27.0 11.3 20.2 26.9 26.3 11.1 20.4 26.9 25.5 71 -15.4 21.3 21.5 -15.6 22.0 22.2 -15.9 22.7 22.9 -15.5 22.2 21.6 -15.2 21.7 20.3 68 -12.4 18.3 18.5 -12.1 18.4 18.7 -11.8 18.6 18.8 -10.9 17.6 17.0 -10.0 16.5 15.1 105 °F Net Cap MBH 36.2 33.9 30.8 31.2 37.6 35.1 32.0 32.4 38.9 36.4 33.1 33.6 39.4 36.8 33.5 34.0 39.9 37.3 33.9 34.4 Total Power Input kW 4.40 4.28 4.20 4.22 4.47 4.35 4.27 4.29 4.54 4.42 4.34 4.35 4.69 4.57 4.48 4.50 4.84 4.71 4.63 4.64 Sensible CapacityMBH1Entering DryBulb ° F 86 22.4 29.3 30.8 31.2 24.8 32.1 32.0 32.4 27.3 34.9 33.1 33.6 29.3 36.1 33.5 34.0 31.4 37.3 33.9 34.4 83 19.4 26.3 30.5 31.2 21.3 28.8 31.8 32.4 23.2 31.3 33.1 33.6 24.7 33.2 33.5 34.0 26.2 35.1 33.9 34.4 80 16.4 23.3 27.8 28.8 17.7 25.3 30.1 31.2 19.1 27.2 32.4 33.6 20.0 28.6 33.1 34.0 21.0 29.9 33.9 34.4 77 13.4 20.3 24.8 25.8 14.2 21.7 26.5 27.6 15.0 23.1 28.3 29.5 15.4 23.9 28.5 29.3 15.8 24.7 28.7 29.1 74 10.4 17.3 21.8 22.8 10.7 18.2 23.0 24.1 10.9 19.0 24.2 25.4 10.7 19.3 23.8 24.7 10.6 19.5 23.5 23.9 71 -14.3 18.8 19.8 -14.7 19.4 20.6 -15.0 20.1 21.3 -14.6 19.2 20.0 -14.3 18.3 18.7 68 -11.4 15.8 16.8 -11.1 15.9 17.0 -10.9 16.0 17.2 -10.0 14.5 15.4 -9.1 13.1 13.5 115 °F Net Cap MBH 33.8 31.1 27.7 29.8 35.0 32.2 28.8 30.9 36.3 33.4 29.8 32.0 36.7 33.8 30.1 32.3 37.2 34.2 30.5 32.7 Total Power Input kW 4.64 4.51 4.44 4.46 4.71 4.58 4.51 4.53 4.78 4.65 4.58 4.59 4.94 4.80 4.73 4.75 5.09 4.96 4.88 4.90 Sensible CapacityMBH1Entering DryBulb ° F 86 21.7 28.3 27.7 29.8 24.2 30.8 28.8 30.9 26.7 33.4 29.8 32.0 28.8 33.8 30.1 32.3 30.9 34.2 30.5 32.7 83 18.7 25.3 27.7 29.8 20.7 27.8 28.8 30.9 22.6 30.3 29.8 32.0 24.2 32.3 30.1 32.3 25.7 34.2 30.5 32.7 80 15.7 22.3 25.3 27.1 17.1 24.3 27.5 29.5 18.5 26.3 29.8 32.0 19.5 27.7 30.1 32.3 20.5 29.1 30.5 32.7 77 12.7 19.3 22.3 24.1 13.6 20.7 24.0 26.0 14.4 22.2 25.7 27.9 14.9 23.0 25.5 27.7 15.3 23.8 25.3 27.5 74 9.7 16.3 19.3 21.1 10.0 17.2 20.4 22.5 10.3 18.1 21.6 23.8 10.2 18.4 20.8 23.0 10.1 18.6 20.1 22.3 71 -13.3 16.3 18.1 -13.7 16.9 18.9 -14.0 17.5 19.7 -13.7 16.2 18.4 -13.4 14.8 17.1 68 -10.3 13.3 15.2 -10.1 13.4 15.4 -9.9 13.4 15.6 -9.1 11.5 13.7 -8.2 9.6 11.9 125 °F Net Cap MBH 31.4 28.3 24.6 28.3 32.5 29.3 25.5 29.3 33.6 30.4 26.4 30.3 34.0 30.7 26.7 30.7 34.5 31.1 27.1 31.1 Total Power Input kW 4.9 4.7 4.7 4.7 4.9 4.8 4.7 4.8 5.0 4.9 4.8 4.8 5.2 5.0 5.0 5.0 5.3 5.2 5.1 5.2 Sensible CapacityMBH1Entering DryBulb ° F 86 21.1 27.2 24.6 28.3 23.6 29.6 25.5 29.3 26.1 31.9 26.4 30.3 28.3 31.5 26.7 30.7 30.4 31.1 27.1 31.1 83 18.1 24.2 25.0 28.3 20.0 26.8 25.7 29.3 22.0 29.4 26.4 30.3 23.6 31.3 26.7 30.7 25.2 33.3 27.1 31.1 80 15.1 21.3 22.8 25.5 16.5 23.3 25.0 27.9 17.9 25.3 27.2 30.3 19.0 26.7 27.1 30.7 20.0 28.2 27.1 31.1 77 12.1 18.3 19.8 22.5 13.0 19.7 21.4 24.4 13.9 21.2 23.1 26.3 14.3 22.1 22.5 26.1 14.8 23.0 21.9 25.9 74 9.1 15.3 16.8 19.5 9.4 16.2 17.9 20.8 9.8 17.1 19.0 22.2...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories