|
Instructions York, Modèle AFFINITY BHP024
Fabricant : York Taille : 1.52 mb Nom Fichier : 509c0a0c-6db8-4b0c-adf0-76620aff361c.pdf
Langue d'enseignement:
|
|
|
|
Aller à la télécharger
Facilité d'utilisation
26 ........................................................................................................................................................................................................................................................................................ ........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ Unitary Products Group 036-21528-007-A-1205 DIRECT DRIVE CONDENSER FAN MOTOR HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN INDOOR COIL ECM DIRECT DRIVE BLOWER MOTOR WITH HEAVY GAUGE LONG-LASTING POWDER PAINT TERMINAL BLOCK BACK AND BOTTOM REMOVABLE HIGH-EFFICIENCY BASE RAILS COMPRESSOR RIGIDLY MOUNTED RETURN AIR AND SUPPLY AIR DUCT OPENING HIGH VOLTAGE TERMINAL BLOCK LOW VOLTAGE FINISH FIGURE 1 - UNIT CUT AWAY TABLE 1: RATINGS HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN OUTDOOR COIL DECORATIVE PROTECTIVE COIL GUARD SLIDE-OUT BLOWER ASSEMBLY MODEL BHP COOLING CAPACITY1 80 / 67-95°F HSPF1 SOUND RATING2 (dbels) NET HEATING CAPACITY AVAILABLE ELECTRIC HEAT NOMINAL CAPACITY KW @47°F @17°F MBH SEER EER MBH COP MBH COP SINGLE PHASE THREE PHASE 024 24.4 13.0 11.3 7.7 79 21.8 3.40 11.0 2.00 5.0, 7.5, 10.0 N / A 030 30.0 13.0 11.3 7.7 77 28.2 3.40 16.5 2.20 5.0, 7.5, 10.0, 15.0 10.0, 15.0 036 35.0 13.0 11.3 7.7 77 32.0 3.30 18.9 2.20 5.0, 7.5, 10.0, 15.0 10.0, 15.0 042 42.0 13.0 11.3 7.7 83 42.0 3.40 23.0 2.20 10.0, 15.0 10.0, 15.0 048 47.0 13.0 11.3 7.7 82 45.0 3.30 25.8 2.20 10.0, 15.0, 20.0, 25.0 10.0, 15.0, 20.0, 25.0 060 55.0 13.0 11.2 7.7 83 56.5 3.30 33.2 2.15 10.0, 15.0, 20.0, 25.0 10.0, 15.0, 20.0, 25.0 1. Certified in accordance with the Uniary Small Equipment certification program, which is based on ARI Standard 210/240. 2. Rated in accordance with ARI Standard 270. SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supplementary resistance (BTU’s per hour) divided by the total electric input (watts) x 3.412. TABLE 2: PHYSICAL DATA MODELS BHP 024 030 036 042 048 060 INDOOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) FAN MOTOR HP (ECM) 10 X 8 1/2 10 X 8 1/2 11 x 10 3/4 11 x 10 3/4 11 X 10 3/4 11 X 10 1 INDOOR COIL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) 2 15 4.38 3 13 4.38 3 15 4.38 3 16 5.63 3 16 5.63 3 16 5.63 OUTDOOR FAN PROPELLER DIA. (in.) FAN MOTOR HP NOM. CFM TOTAL 22 1/4 1,800 22 1/4 1,800 22 1/4 2,400 22 1/4 2,400 22 1/4 3,000 22 1/2 3,000 OUTDOOR COIL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) 1 20 11.7 1 20 11.7 2 20 11.7 2 20 16.4 2 20 16.4 2 20 16.4 CHARGE REFRIGERANT 22 (lbs./oz.) 5 / 5 5 / 15 8 / 8 9 / 14 12 / 0 10 / 4 FILTER FACE AREA (Sq. Ft. / Qty. / Size) 4.28 / 2 / 14 x 22 COMPRESSOR Hermetic Type, Qty. = 1 Reciprocating Scroll Scroll Scroll Scroll Scroll Unitary Products Group 036-21528-007-A-1205 TABLE 3: COOLING CAPACITIES - 2 TON (BHP024) TEMPERATURE AIR ON OUTDOOR COIL TEMPERATURE OF AIR ON INDOOR COIL 800 CFM 900 CFM WB °F WB °F 72 67 62 57 72 67 62 57 85 °F NET CAP. MBH 29.1 26.0 23.8 23.4 29.7 26.6 24.3 23.9 POWER INPUT kW 1.93 1.91 1.88 1.87 1.95 1.93 1.91 1.90 Sensible CapacityMBH1Entering DryBulb °F 86 19.2 23.1 23.8 23.4 20.9 25.1 24.3 23.9 83 16.9 20.8 23.8 23.4 18.3 22.5 24.3 23.9 80 14.5 18.5 21.9 22.7 15.6 19.8 23.4 23.6 77 12.2 16.1 19.5 20.3 12.9 17.2 20.7 20.9 74 9.9 13.8 17.2 18.0 10.3 14.5 18.0 18.2 71 #N/A 11.5 14.9 15.7 #N/A 11.9 15.4 15.6 68 #N/A 9.1 12.5 13.3 #N/A 9.2 12.7 12.9 95 °F NET CAP. MBH 27.2 24.2 22.1 22.0 27.7 24.6 22.5 22.4 POWER INPUT kW 2.07 2.06 2.02 2.02 2.09 2.08 2.05 2.04 Sensible CapacityMBH1Entering DryBulb ° F 86 18.6 22.3 22.1 22.0 20.1 23.7 22.5 22.4 83 16.2 20.0 22.1 22.0 17.5 21.5 22.5 22.4 80 13.9 17.7 20.8 21.4 14.8 18.9 21.8 22.1 77 11.6 15.3 18.4 19.0 12.2 16.2 19.2 19.4 74 9.2 13.0 16.1 16.7 9.5 13.5 16.5 16.8 71 #N/A 10.7 13.8 14.4 #N/A 10.9 13.8 14.1 68 #N/A 8.3 11.4 12.0 #N/A 8.2 11.2 11.5 105 °F NET CAP. MBH 23.8 22.4 20.5 20.6 24.2 22.8 20.8 20.9 POWER INPUT kW 2.20 2.21 2.17 2.16 2.24 2.24 2.20 2.19 Sensible CapacityMBH1Entering DryBulb ° F 86 19.5 21.5 20.5 20.6 20.4 22.3 20.8 20.9 83 17.2 19.2 20.5 20.6 18.5 20.7 20.8 20.9 80 14.9 16.9 19.7 20.0 15.9 18.1 20.4 20.6 77 12.6 14.6 17.4 17.7 13.3 15.4 17.8 18.0 74 10.2 12.2 15.1 15.3 10.6 12.7 15.1 15.3 7...
Écrivez votre propre critique du dispositif
|
|